Composition and morphology of wear debris in failed uncemented total hip replacement
Abstract
Interfacial membranes collected at revision from 11 failed uncemented Ti-alloy total hip replacements were examined. Particles in the membranes were characterised by electron microscopy, microchemical spectroscopy and particle size analysis. Most were polyethylene and had a mean size of 0.53 micron +/- 0.3. They were similar to the particles seen in the base resin used in the manufacture of the acetabular implants. Relatively few titanium particles were seen. Fragments of bone, stainless steel and silicate were found in small amounts. Most of the polyethylene particles were too small to be seen by light microscopy. Electron microscopy and spectroscopic techniques are required to provide an accurate description of this debris.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The byproducts of wear include particulate polymeric, ceramic and metallic debris (mostly in the nano, submicron, and micron size range) and in the case of metal-on-metal implants, metallic ions [143]. These byproducts are well known to cause pro-inflammatory responses which can persist for the life of the implant [144,145].”
From Macrophage polarization: an opportunity for improved outcomes in biomaterials and regenerative medicine (2012) · cites this paper as [143]
Citations
Cited by
Sorted by citations
Items 201–300 of 325
Stachowiak, G., Stachowiak, G., & Campbell, P. (1997) · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · doi:10.1243/0954411961534620 · Cited by 21
Yang, M., Zhang, Z., Hahn, C., Laroche, G., King, M. W., & Guidoin, R. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:1 · Cited by 43
Sharma, R., & Balani, K. (2014) · doi:10.1088/0022-3727/47/34/345301 · Cited by 20
Wang, Q., Zhang, D., & Ge, S. (2007) · doi:10.1243/13506501jet232 · Cited by 20
Pawak, V. S., Bhatt, V. K., Sabapathy, M., & Loganathan, V. A. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.135976 · Cited by 23
Isolation and Characterisation of Wear Debris Surrounding Failed Total Ankle Replacements.
Stratton-Powell, A., Williams, S., Tipper, J., Redmond, A., & Brockett, C. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.01.051 · Cited by 19
Murine Model of Progressive Orthopedic Wear Particle-Induced Chronic Inflammation and Osteolysis
Pajarinen, J., Nabeshima, A., Lin, T.-H., Sato, T., Gibon, E., Jämsen, E., Lu, L. Y., Nathan, K., Yao, Z., & Goodman, S. (2017) · Tissue Engineering. Part C, Methods · doi:10.1089/ten.tec.2017.0166 · Cited by 19
Niki, Y., Matsumoto, H., Otani, T., Suda, Y., Yatabe, T., Yoshimine, F., Kondo, M., & Toyama, Y. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00246-1 · Cited by 19
Extent of Inflammation and Foreign Body Reaction to Porous Polyethylene In Vitro and In Vivo
Vollkommer, T., Henningsen, A., Friedrich, R. E., Felthaus, O. H., Eder, F., Morsczeck, C. O., Smeets, R., Gehmert, S., & Gosau, M. (2019) · In Vivo · doi:10.21873/invivo.11479 · Cited by 18
The Hundred Most Cited Publications in Orthopaedic HIP Research - A Bibliometric Analysis
Ahmad, S. S., Albers, C. E., Büchler, L., Kohl, S., Ahmad, S. S., Klenke, F. M., Siebenrock, K. A., & Beck, M. (2016) · Hip International · doi:10.5301/hipint.5000322 · Cited by 17
Bell, J., Tipper, J., Ingham, E., Stone, M. H., Wroblewski, B., & Fisher, J. (2002) · Bio-medical materials and engineering · doi:10.1177/095929892002012002008 · Cited by 18
Characterizing fretting particles by analysis of SEM images.
Gwynn, I. A., & Wilson, C. (2001) · European Cells & Materials · doi:10.22203/ecm.v001a01 · Cited by 18
Liu, S., Hall, D., Della-Valle, C., Walsh, M., Jacobs, J., & Pourzal, R. (2021) · Biotribology · doi:10.1016/j.biotri.2021.100163 · Cited by 17
Self-citationPopoola, O., Orozco-villasenor, D. A., Fryman, J., Mimnaugh, K., & Rufner, A. S. (2018) · Biotribology · doi:10.1016/j.biotri.2018.09.001 · Cited by 17
Elke, R., & Rieker, C. (2018) · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · doi:10.1177/0954411918784982 · Cited by 17
Meyer, D., Tillinghast, A., Hanumara, N., & Franco, A. (2006) · doi:10.1115/1.2162554 · Cited by 17
Lavigne, P., Shi, Q., Lajeunesse, D., Dehnade, F., & Fernandes, J. (2003) · Bone · doi:10.1016/j.bone.2003.10.006 · Cited by 12
Migration of polyethylene debris along well-fixed cemented implants.
Massin, P., Viguier, E., Flautre, B., Hardouin, P., Astoin, E., & Duponchel, B. (2004) · Journal of Biomedical Materials Research. Part B - Applied biomaterials · doi:10.1002/jbm.b.10072 · Cited by 17
Technique for generating submicrometer ultra high molecular weight polyethylene particles
Shanbhag, A. S., Hasselman, C., & Rubash, H. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140622 · Cited by 17
Self-citationMostafa, A. A., Drüen, S., Nolte, I. J. A., & Wefstaedt, P. (2011) · Veterinary Surgery · doi:10.1111/j.1532-950x.2011.00931.x · Cited by 21
Stratton-Powell, A., Williams, S., Tipper, J., Redmond, A., & Brockett, C. (2022) · Journal of Biomedical Materials Research. Part B - Applied biomaterials · doi:10.1002/jbm.b.35076 · Cited by 16
“These results have since been generally representative of the wear particle sizes isolated from tissue samples for both THR and TKR.25,26,33,34 However, the size distribution was skewed in favor of the larger and visually defined particle types which were often agglomerates of wear debris rather than individual partic…”
BackgroundResultInfluentialMigration of wear debris of polyethylene depends on bone microarchitecture.
Libouban, H., Massin, P., Gaudin, C., Mercier, P., Baslé, M., & Chappard, D. (2009) · Journal of Biomedical Materials Research. Part B - Applied biomaterials · doi:10.1002/jbm.b.31341 · Cited by 16
Circulating blood monocytes traffic to and participate in the periprosthetic tissue inflammation
Zhang, K., Jia, T., Mcqueen, D., Gong, W., Markel, D., Wooley, P., & Yang, S.-Y. (2009) · Inflammation Research · doi:10.1007/s00011-009-0051-5 · Cited by 16
“ent in the tissues, frequently engulfed or in close contact with macrophages [4, 5].”
Jehn, C. T., & Manley, P. (2002) · Veterinary surgery · doi:10.1053/jvet.2002.33614 · Cited by 16
Surface Topography of Retrieved PCA Acetabular Liners: Proposal of a Novel Wear Mechanism
Elfick, A., Hall, R. M., Unsworth, A., & Pinder, I. (1998) · doi:10.1023/a:1006623830833 · Cited by 16
Zhang, K., Yang, S.-Y., Yang, S.-Y., Bai, L., Li, P., Liu, D., Schurman, J. R., & Wooley, P. (2015) · Journal of Biomedical Materials Research. Part A · doi:10.1002/jbm.a.35176 · Cited by 16
Pakhaliuk, V., Polyakov, A., Kalinin, M., & Bratan, S. (2016) · doi:10.2474/trol.11.527 · Cited by 15
“It leads to progressive wear of a ball head and an acetabular component of prosthesis, as well as to aseptic instability of its components [1,2].”
BackgroundBaxter, R. M., Ianuzzi, A., Freeman, T., Kurtz, S., & Steinbeck, M. (2010) · Journal of Biomedical Materials Research. Part A · doi:10.1002/jbm.a.32813 · Cited by 15
An elastohydrodynamic lubrication (EHL) model of wear particle migration in an artificial hip joint
Jhurani, S. M., & Higgs, C. (2010) · doi:10.1016/j.triboint.2009.12.069 · Cited by 15
Intracellular measurement of polyethylene particles
von Knoch, M., Buchhorn, G., vonKnoch, F., Köster, G., & Willert, H. (2001) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s004020000256 · Cited by 15
Influence of particle size in the effect of polyethylene on human osteoblastic cells.
Rodrigo, A., Martínez, M. E., Escudero, M., Ruiz, J. A., Martínez, P., Saldaña, L., Gómez-García, L., Fernández, L., Cordero, J., & Munuera, L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00208-8 · Cited by 15
Characteristics of Particles and Debris Released after Implantoplasty: A Comparative Study
Wu, X., Cai, C., Gil, J., Jantz, E., Sakka, Y. A., Padial‐Molina, M., & Suárez, F. (2022) · Materials · doi:10.3390/ma15020602 · Cited by 16
“Moreover, different compositions, concentrations, morphologies and sizes of metal particles exert different cytotoxic effects [19].”
BackgroundPlate Fixation of Prostheses after Segmental Resection for Bone Tumours
Coathup, M., Cobb, J., Walker, P. S., & Blunn, G. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180604 · Cited by 14
Particulate retrieval of hydrolytically degraded poly(lactide-co-glycolide) polymers
Cordewener, F. W., Dijkgraaf, L. C., Ong, J. L., Agrawal, C. M., Zardeneta, G., Milam, S. B., & Schmitz, J. P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200004)50:1 · Cited by 15
Review of models for titanium as a foreign body.
Frydman, A., & Simonian, K. (2014) · Journal - California Dental Association · doi:10.1080/19424396.2014.12221450 · Cited by 13
Verschleiß und aseptische Prothesenlockerung
Kaddick, C., Catelas, I., Pennekamp, P., & Wimmer, M. A. (2009) · Der Orthopade · doi:10.1007/s00132-009-1431-9 · Cited by 13
Gene Expression Profile of Macrophage-Like U937 Cells in Response to Polyethylene Particles
Matsusaki, T., Kawanabe, K., Ise, K., Nakayama, T., Toguchida, J., & Nakamura, T. (2007) · The Journal of Arthroplasty · doi:10.1016/j.arth.2007.03.013 · Cited by 14
“Polyethylene (PE) is widely used for artificial joint surfaces, and submicronic PE particles are the main component of wear particles [7,8].”
BackgroundAllergic reactions to metal implants
Thomas, P., Maier, S., & Summer, B. (2004) · doi:10.1002/mawe.200400842 · Cited by 13
Ultra-High Molecular Weight Polyethylene Wear Particle Effects on Bioactivity | NIST
Fang, H.-W., Hsu, S. M., & Sengers, J. V. (2003) · doi:10.6028/nist.sp.1002 · Cited by 13
“1 Availability of narrowly distributed particles From clinical retrieval studies of wear particles, it is known that various sizes and shapes of UHMWPE particles are generated from total joint replacements [35-42].”
BackgroundThe National Cancer Data Base report on colon cancer
Jessup, J. M., McGinnis, L. S., Steele, G. D., Menck, H. R., & Winchester, D. P. (1996) · Cancer · doi:10.1002/(sici)1097-0142(19960815)78:4 · Cited by 259
Is polyethylene still the best prosthetic bearing surface?
Amis, A. A. (1996) · Journal of Bone and Joint Surgery-british Volume · doi:10.1302/0301-620x.78b3.0780345 · Cited by 13
Rolf, O., Baumann, B., Sterner, T., Schütze, N., Jakob, F., Eulert, J., & Rader, C. (2005) · Biomedizinische Technik. Biomedical engineering · doi:10.1515/bmt.2005.005 · Cited by 13
“A lot of studies focused on the characterization of mode I-wear particles in aseptic loosening [8,17] but data for metallose wear particles (mode II-wear) and their effects in vitro and in vivo are limited.”
BackgroundMethodSittinger, M., Reitzel, D., Dauner, M., Hierlemann, H., Hammer, C., Kastenbauer, E. R., Planck, H., Burmester, G. R., & Bujía, J. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199622)33:2 · Cited by 226
On the fate of particles liberated from hydroxyapatite coatings in vivo
Dunne, C. F., Gibbons, J., FitzPatrick, D. P., Mulhall, K. J., & Stanton, K. T. (2015) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-014-1243-8 · Cited by 14
“Secondly, in revision cases due to loosening of the prostheses, particles of debris from all components of the prosthetic joint, not only HA, will be found at revision [50].”
BackgroundMartínez, M. E., Medina, S., del Campo, M. D., Sánchez-Cabezudo, M., Sánchez, M., & Munuera, L. (1998) · Calcified Tissue International · doi:10.1007/s002239900459 · Cited by 12
“It appears that the ultra-high molecular weight polyethylene particles and metal debris have an important role in this mechanism [6, 7].”
BackgroundStilling, M. (2009) · Acta Orthopaedica · doi:10.3109/17453670903420819 · Cited by 11
Prevention of Loosening in Total Hip Replacements Using Guided Bone Regeneration
Bhumbra, R., Walker, P., Berman, A., Emmanual, J., Barrett, D., & Blunn, G. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200003000-00021 · Cited by 11
Histological evaluation of bone—cement interface affected by polyethylene particles in rabbit knee
Ohashi, H., Kobayashi, A., Yoshida, K., Yutani, Y., Yamano, Y., Oonishi, H., & Iwaki, H. (1994) · doi:10.1007/bf00120340 · Cited by 11
Patel, J. V., Lal, S., Nuss, K., Wilshaw, S., von Rechenberg, B., Hall, R. M., & Tipper, J. L. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.02.030 · Cited by 10
“Such protocols have included sodium hydroxide [7–11], potassium hydroxide [12–14] and nitric acid [15–17].”
Textured bearing surface in artificial joints to reduce macrophage activation
Nakanishi, Y., Nishi, N., Chikaura, H., Nakashima, Y., Miura, H., Higaki, H., Mizuta, H., Iwamoto, Y., Fujiwara, Y., Komohara, Y., et al. (2015) · doi:10.1088/2051-672x/3/4/044005 · Cited by 10
Ercan, B., & Webster, T. (2014) · doi:10.1201/b17444-10 · Cited by 10
Femoral osteolysis after low-friction arthroplasty. A planimetric study and volumetric estimate.
Garcia-Cimbrelo, E., Madero, R., Blasco-Alberdi, A., & Munuera, L. (1997) · Journal of Arthroplasty · doi:10.1016/s0883-5403(97)90134-0 · Cited by 10
Factors contributing to the wear of polyethylene in clinical practice
Learmonth, I., & Cunningham, J. (1997) · Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine · doi:10.1243/0954411971534674 · Cited by 10
Wear Mechanisms in Ceramic Hip Implants
Slonaker, M., & Goswami, T. (2004) · Journal of Surgical Orthopaedic Advances · doi:10.1515/jmbm.2004.15.1-2.49 · Cited by 10
Vara, J., Delgado, J., Estrada-Martínez, A., Pérez-Pevida, E., Brizuela, A., Bosch, B., Pérez, R., & Gil, J. (2022) · Coatings · doi:10.3390/coatings12020219 · Cited by 9
Mechanical properties of femoral cortical bone following cemented hip replacement
Ni, G., Lu, W.-W., Chiu, P., Wang, Y., Li, Z.-Y., Zhang, Y.-G., Xu, B., Deng, L.-F., & Luk, K. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20388 · Cited by 9
Ceramic-on-Ceramic Bearings for Total Hip Arthroplasty: 5-9 Year Follow-Up
D'Antonio, J., Capello, W., Bierbaum, B., Manley, M., & Naughton, M. (2006) · doi:10.1053/j.sart.2006.09.009 · Cited by 9
The Inert-Bioactivity Conundrum
Williams, D. F. (2003) · CRC Press eBooks · doi:10.1201/9780203491430.ch23 · Cited by 11
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3 · Cited by 671
Study on wear reduction mechanism of artificial joints grafted with hydrophilic polymer membranes
Sawano, H., Warisawa, S., & Ishihara, S. (2009) · Wear · doi:10.1016/j.wear.2009.07.016 · Cited by 9
Biotribology: Material Design, Lubrication, and Wear in Artificial Hip Joints
Fisher, J., Ingham, E., & Jin, Z. (2006) · doi:10.1201/9781420003840.ch17 · Cited by 8
Gene expression of bone-resorbing cytokines in rat osteolysis model
Kobayashi, Y., Kim, K.-J., & Itoh, T. (2005) · Journal of Orthopaedic Science · doi:10.1007/s00776-004-0846-8 · Cited by 8
Particle disease: Cytopathologic findings of an unusual case
Parwani, A., Yang, B., Clark, D. P., & Ali, S. Z. (2004) · Diagnostic Cytopathology · doi:10.1002/dc.20102 · Cited by 8
Lidor, C., McDonald, J. W., Roggli, V., & Vail, T. P. (1996) · Journal of Urology · doi:10.1016/s0022-5347(01)65517-4 · Cited by 8
Polyethylene wear rates with Zirconia and cobalt chrome heads in the ABG hip
Skyrme, A., Richards, S., John, A., Chia, M., Walter, W., Walter, W., & Zicat, B. (2005) · HIP International · doi:10.1177/112070000501500201 · Cited by 8
“Analysis of the membranes around aseptically loosened components has revealed that polyethylene debris is a major factor activating macrophages via the cytokine pathway, leading to bone resorption (4-6).”
BackgroundAminatun, Hikmawati, D., & Yasin, M. (2017) · doi:10.4028/www.scientific.net/jbbbe.32.59 · Cited by 7
“Aseptic loosening occurs because the particles migrate along the bone-implant interface form a fibrous membrane, especially around the acetabular component [2].”
BackgroundCyndari, K., Goodheart, J. R., Miller, M. A., Oest, M. E., Damron, T., & Mann, K. (2017) · Journal of Arthroplasty · doi:10.1016/j.arth.2017.01.047 · Cited by 7
“As has been reported by other groups [10,12,14,23], the morphology of these particles included filaments and lenticular shapes, which were visible as individual particles or in clumps (Fig.”
Effect of acetabular orientation on stress distribution of highly cross-linked polyethylene liners.
Lam, L., Drew, T., & Boscainos, P. (2013) · Orthopedics · doi:10.3928/01477447-20131021-13 · Cited by 7
Ikema, M., Oyama, M., Kita, A., & Funayama, K. (2007) · Journal of Orthopaedic Science · doi:10.1007/s00776-007-1161-y · Cited by 7
Bearing Surfaces for Joint Replacement: New Materials or New Problems
Goodman, S. (2014) · doi:10.1007/978-1-4614-8999-3_2 · Cited by 7
Characterization of UHMWPE Wear Particles
Stratton-Powell, A., & Tipper, J. (2009) · doi:10.1016/b978-0-12-374721-1.00027-4 · Cited by 7
Crainic, A. M., Callisti, M., Palmer, M. R., & Cook, R. B. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34134 · Cited by 5
Biological causes of prosthetic joint failure
Revell, P. A. (2014) · Elsevier eBooks · doi:10.1533/9780857098474.3.298 · Cited by 6
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89
A Wavelet based Method for QRS Complex Detection
Farashi, S. (2012) · doi:10.5923/j.ajbe.20110101.02 · Cited by 5
“[67] Shanbhag AS, Jacobs JJ, Glant TT, Gilbert JL, Black J, Galante JO.”
Evaluation of cytotoxicity of UHMWPE wear debris
Rao, S., Shirata, K., Furukawa, K., Ushida, T., Tateishi, T., Kanazawa, M., Katsube, S., & Janna, S. (1999) · Bio-medical materials and engineering · doi:10.1177/095929891999009004002 · Cited by 5
“Many reports suggest that retrieved periprosthetic tissues contain significant volumes of ultra-high-molecular-weight-polyethylene (UHMWPE) particles [1–5].”
Microscale Applications in Tribology
Reeves, C., Menezes, P., Lovell, M., & Jen, T.-C. (2013) · doi:10.1007/978-1-4614-1945-7_27 · Cited by 5
Biological response to artificial discs
Revell, P. A. (2012) · Elsevier eBooks · doi:10.1533/9780857096197.2.313 · Cited by 5
LUBRICATION AND WEAR OF ZIRCONIA-ON-METAL TOTAL HIP REPLACEMENTS
Smith, S. S., Goldsmith, A., & Dowson, D. (2002) · doi:10.1016/s0167-8922(02)80042-6 · Cited by 5
Biomaterial Properties of Femur Implant on Acetabulum Erosion: A Review
Pimpale, S., Deshmukh, M., Shelke, R., & Deshmukh, D. S. (2021) · doi:10.4028/www.scientific.net/jbbbe.51.39 · Cited by 4
Zhang, M., Wang, J.-Y., Su, J., Wang, J.-J., Yan, S.-T., Luan, Y., & Cheng, C.-K. (2021) · Polymers · doi:10.3390/polym13111847 · Cited by 4
“1 μm and 1 μm, in which range the particles have been implicated in the onset of bone osteolysis [25].”
BackgroundYokhana, S., Bergum, C., Ren, W., & Markel, D. (2018) · The journal of knee surgery · doi:10.1055/s-0038-1666831 · Cited by 4
Fulin, P., Pokorny, D., Šlouf, M., Lapčíková, M., Pavlová, E., Zolotarevová, E., Entlicher, G., Jahoda, D., & Sosna, A. (2011) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2011/021 · Cited by 4
Pokorny, D., Šlouf, M., Horák, Z., Jahoda, D., Entlicher, G., Eklová, S., & Sosna, A. (2006) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2006/035 · Cited by 4
“Nejdůležitějším z nich je přítomnost otěrových částic polyetylenu (UHMWPE) o velikosti pod 1 m (9, 18, 19, 21, 22).”
CERAMIC/CERAMIC TOTAL HIP REPLACEMENT: THE AMERICAN EXPERIENCE WITH STRYKER IMPLANTS
Bierbaum, B., D'Antonio, J., Capello, W., Manley, M., & Deshmukh, R. (2004) · doi:10.1007/978-3-7985-1968-8_5 · Cited by 4
Itonaga, I., Kato, S., Torisu, T., & Masumi, S. (1997) · doi:10.1007/bf01239755 · Cited by 4
Abriebverhalten von zementierten Hüftendoprothesen-Stielen*
Bader, R., Mittelmeier, W., Steinhauser, E., Brehm, P., Brem, R., Tübel, J., P. Choungthong, Winklmair, D., Schmitt, M., & Holzwarth, U. (2005) · doi:10.3139/120.100648 · Cited by 3
Versagensursachen primärer Implantationen
Baumann, B., Fuerst, M., Kirschner, S., Lohmann, C., Nuechtern, J., Rader, C., Ruether, W., Seifert, J., & Zustin, J. (2008) · doi:10.1007/978-3-540-75649-1_2 · Cited by 3
Kusuma, S. K., & Garino, J. (2007) · doi:10.1016/b978-0-323-03370-1.50013-7 · Cited by 3
Biological Response to Particulate Debris from Nonmetallic Orthopedic Implants
Pappas, M., Schmidt, C., Shanbhag, A. S., Whiteside, T., Rubash, H., & Herndon, J. (1996) · doi:10.1007/978-1-4757-2487-5_6 · Cited by 3
Self-citationBaumann, B., Rolf, O., Jakob, F., Goebel, S., Sterner, T., Eulert, J., & Rader, C. (2006) · Biomedizinische Technik. Biomedical engineering · doi:10.1515/bmt.2006.070 · Cited by 2
Biology of Foreign Bodies: Tolerance, Osteolysis, and Allergy
Nasser, S. (2005) · doi:10.1007/3-540-27658-0_55 · Cited by 2
Kawate, K., Ohmura, T., Hiyoshi, N., Nakajima, H., Natsume, Y., Teranishi, T., Tamai, S., & Nanzai, Y. (1999) · doi:10.1007/978-4-431-68529-6_9 · Cited by 2
Progress in Prevention and Treatment of Acute Bone Loss in Orthopedics
Wang, H., Wu, J., Wang, B., Qin, H., Fan, L., Wang, Y.-H., & He, B. (2023) · International Journal of Endocrinology · doi:10.1155/2023/9373043 · Cited by 1
“After trauma, osteoclasts are activated under the action of various infammatory factors and proliferate in large numbers [19, 20], thus cooperating with immune cells to release a large number of proin-fammatory factors [21], especially tumor necrosis factor-α (TNF-α ), interleukin-1 (IL-1), and…”
Backgroundvon Skrbensky, G., Mühlbacher, K., Benca, E., Kolb, A., Windhager, R., Reischl, G., & Reinisch, G. (2019) · Italian National Conference on Sensors · doi:10.3390/s19173751 · Cited by 1
Steel Contamination of Biomedical Titanium Alloys during Hot Isostatic Pressing Treatments
Marin, E., Lanzutti, A., & Fedrizzi, L. (2014) · Metallography Microstructure and Analysis · doi:10.1007/s13632-014-0123-y · Cited by 1
“Fragments from machining tools or sandblasting particles [29], impurities in the autoclave steam moisture during sterilization [30], inadequate surface preparation/passivation [31], the presence of bone fragments during surgery [32] and, in general, every step between raw material production and implantation adds a sm…”
BackgroundA Quantitative Model of Wear Loss Based on On-Line Visual Ferrograph
Wang, C.-H., Yuan, W.-Y., Dong, G., & Mao, J. (2013) · doi:10.4028/www.scientific.net/amm.330.338 · Cited by 1
“The wear particles in the lubricant are satisfied some inherent distribution [6-11].”
BackgroundBilli, F., Benya, P., Kavanaugh, A., Adams, J. S., Ebramzadeh, E., & Mckellop, H. (2012) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-2057-x · Cited by 1
“The first protocol, originally developed at our research center in the 1990s [8], has been widely used [24, 31, 46, 48] and is hereinafter referred to as the NaOH protocol.”
Cytokines and Mediators in Physiologic and Pathologic Bone Resorption
Haynes, D., & Crotti, T. (2005) · doi:10.1201/b14138-13 · Cited by 1
Foreign Body Granulomatous Response to Particulate Bony Debris
Boss, J., Ish-Shalom, Z., Misselevich, I., & Mendes, D. (1996) · Veterinary and comparative orthopaedics and traumatology · doi:10.1055/s-0038-1632516 · Cited by 1
“Tiny calcium phosphaterich particles, remnants of drilling, reaming and curettage or bone-implant interfacial abrasion products, constitute another type of periprosthetic debris (49).”
Background
Metadata
- Authors
- Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J.
- Affiliations
- Rush University (US)
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1994-01
- Volume
- 76-B
- Issue
- 1
- Pages
- 60-67
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W1914858881
- Cited by
- 387
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 5 · 2016: 5 · 2015: 4 · 2014: 12 · 2013: 11 · 2012: 9
- FWCI
- 26.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery - British Volume (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Keywords
- wear debris, cementless total hip arthroplasty, revision hip arthroplasty, polyethylene wear particles, titanium alloys, interfacial membrane, particle size, implant failure, bone fragments, stainless steel particles, silicate particles
- MeSH terms
- Aged, Cementation, Female, Hip Joint, Hip Prosthesis, Humans, Male, Microscopy, Electron, Scanning, Middle Aged, Particle Size, Polyethylenes, Prosthesis Failure, Reoperation, Titanium, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review