The DOI matches its Crossref record.
Composition and morphology of wear debris in failed uncemented total hip replacement
Abstract
Interfacial membranes collected at revision from 11 failed uncemented Ti-alloy total hip replacements were examined. Particles in the membranes were characterised by electron microscopy, microchemical spectroscopy and particle size analysis. Most were polyethylene and had a mean size of 0.53 micron +/- 0.3. They were similar to the particles seen in the base resin used in the manufacture of the acetabular implants. Relatively few titanium particles were seen. Fragments of bone, stainless steel and silicate were found in small amounts. Most of the polyethylene particles were too small to be seen by light microscopy. Electron microscopy and spectroscopic techniques are required to provide an accurate description of this debris.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The byproducts of wear include particulate polymeric, ceramic and metallic debris (mostly in the nano, submicron, and micron size range) and in the case of metal-on-metal implants, metallic ions [143]. These byproducts are well known to cause pro-inflammatory responses which can persist for the life of the implant [144,145].”
From Macrophage polarization: an opportunity for improved outcomes in biomaterials and regenerative medicine (2012) · cites this paper as [143]
Citations
Cited by
Sorted by citations
Items 301–325 of 325
Biological causes of prosthetic joint failure
Revell, P. A. (2008) · Elsevier eBooks · doi:10.1533/9781845694807.3.349 · Cited by 14
In vitro macrophage response to nanometer-size particles from materials used in hip implants
Vanos, R. (2011) · doi:10.20381/ruor-4714 · Cited by 1
“The biological response to wear particles has been shown to vary primarily with particle composition, size, shape and number [14, 21, 22, 29, 50-52, 79].”
BackgroundSouffrant, R., Ellenrieder, M., Kluess, D., Mittelmeier, W., & Bader, R. (2010) · doi:10.1007/978-3-642-14515-5_204 · Cited by 1
Ätiologie und Pathogenese der periprothetischen Osteolyse
Baumann, B., & Rader, C. (2008) · doi:10.1007/978-3-7985-1825-4_11 · Cited by 1
Allergic reactions to metal implants: influence of wear debris
Thomas, P., & Summer, B. (2005) · doi:10.1007/3-7985-1540-9_4 · Cited by 1
Sawicki, J., Danielewicz, A., Wójciak, M., Latalski, M., Skalska-Kamińska, A., Tyszczuk-Rotko, K., & Sowa, I. (2021) · Molecules · doi:10.3390/molecules26082120
“tissue from patients with a Ti-alloy hip prosthesis 4M KOH 56 ◦C 48 h (two times) [14]”
BackgroundHuman polyethylene granuloma tissues inhibit bone healing in a novel xenograft animal model
Esposito, C., Oliver, R., Campbell, P., Yu, Y., Walter, W., Walter, W., & Walsh, W. R. (2013) · Journal of Orthopaedic Research · doi:10.1002/jor.22588
Prothèse totale de la hanche chez le chien
Pucheu, B., & Duhautois, B. (2011) · EMC - Vétérinaire · doi:10.1016/s1283-0828(11)54740-4
COMBINED EFFECTS OF POLYETHYLENE WEAR PARTICLE SIZE AND DOSAGE ON MACROPHAGE RESPONSES
Chang, C.-H., Fang, H.-W., Ho, Y.-C., Lin, C.-Y., Huang, C.-H., & Yang, C.-B. (2010) · doi:10.4015/s1016237210002018
Jin, Z.-M., Tipper, J., Stone, M., Ingham, E., & Fisher, J. (2006) · doi:10.1002/0471732877.emd280
In Vitro and In Vivo Models for Understanding Osteolysis
Puskas, B., & Neavyn, M. (2005) · doi:10.1201/b14138-20
Shanbhag, A. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.004
Self-citationPresence of silicon in massive osteolysis after cementless total hip arthroplasty: Case report
Shindo, H., Warabi, S., Taneda, H., & Azuma, H. (1997) · doi:10.1007/bf02489519
Munir, K., Biesiekierski, A., Wen, C., & Li, Y.-C. (2021) · Structural Biomaterials · doi:10.1016/b978-0-12-818831-6.00009-4
The Biology of Aseptic Loosening
Karachalios, T., & Koutalos, A. (2014) · Springer eBooks · doi:10.1007/978-1-4471-5409-9_11
Immuno-allergological Aspects of Adverse Reactions in Total Joint Replacement
Thomas, P., & Summer, B. (2003) · doi:10.1007/978-3-642-85763-8_11
The Metal/Polyethylene Interface
Tipper, J., Besong, A. A., Minakawa, H., Stone, M., Wroblewski, B., Ingham, E., & Fisher, J. (2000) · doi:10.1007/978-1-4471-0477-3_10
Localized Osteolysis after Joint Replacement Surgery
Shanbhag, A. S., & Rubash, H. E. (2000) · Springer eBooks · doi:10.1007/978-1-4471-3825-9_40
Self-citationWear Debris Analysis for Total Hip and Total Knee Arthroplasty
Hirakawa, K., Bauer, T., Stulberg, B., Yamaguchi, M., Koshino, T., & Saito, T. (1999) · doi:10.1007/978-4-431-68529-6_4
Characteristics of Wear Particles and Osteolysis
Ohashi, H., Kadoya, Y., Kobayashi, A., Iwaki, H., & Yamano, Y. (1999) · Springer eBooks · doi:10.1007/978-4-431-68529-6_3
The Biology of Corrosion and Wear Debris from Orthopedic Implants
Jacobs, J., & Glant, T. (1998) · MRS Proceedings · doi:10.1557/proc-550-321
Self-citation- Self-citation
Rhodes (1997) · doi:10.1002/(sici)1097-4636(19971215)37:4
Metadata
- Authors
- Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J.
- Affiliations
- Rush University (US)
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1994-01
- Volume
- 76-B
- Issue
- 1
- Pages
- 60-67
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W1914858881
- Cited by
- 387
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 3 · 2023: 4 · 2022: 3 · 2021: 9 · 2020: 3 · 2019: 3 · 2018: 7 · 2017: 5 · 2016: 5 · 2015: 4 · 2014: 12 · 2013: 11 · 2012: 9
- FWCI
- 26.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery - British Volume (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Keywords
- wear debris, cementless total hip arthroplasty, revision hip arthroplasty, polyethylene wear particles, titanium alloys, interfacial membrane, particle size, implant failure, bone fragments, stainless steel particles, silicate particles
- MeSH terms
- Aged, Cementation, Female, Hip Joint, Hip Prosthesis, Humans, Male, Microscopy, Electron, Scanning, Middle Aged, Particle Size, Polyethylenes, Prosthesis Failure, Reoperation, Titanium, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›