Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The tibial components in 143 patients with total knee replacements performed before 1988 were assessed for micromotion using roentgen stereophotogrammetric analysis (RSA) over a period of 13 years. The fixation of the prostheses remained clinically sound in all cases, although revision had been required for other reasons in seven. In a second group taken from all cases with RSA available on our full database to 1990, 15 tibial components had been followed by RSA from the insertion until, 1 to 11 years after the initial arthroplasty, they were revised for mechanical loosening of the tibial component; 12 of these comprised all the loosenings in the base group, thus making a total of 155 consecutive cases, while an additional three were inserted after the base material had been compiled. The mean migration in the first group was about 1 mm at one year, but subsequent migration was slower, reaching a mean of about 1.5 mm after ten years. About one-third migrated continuously throughout follow-up, while two-thirds ceased to migrate after one to two years. In the revision group, 14 components had migrated continuously and at one year significantly more than those in the first group. One revision case lacked the crucial one-year follow-up and could not be classified. These findings suggest that mechanical loosening begins early in the postoperative period. Clinical symptoms which necessitate revision, seen at this stage in 20% of abnormally migrating tibial components, may not appear until up to ten years after the operation.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_20 · Cited by 783
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Willert, H. G., Bertram, H., & BUCHHORN, G. H. (1990) · PubMed · Cited by 387
Endosteal erosion in association with stable uncemented femoral components.
Maloney, W. J., Jasty, M., Harris, W. H., Galante, J. O., & Callaghan, J. J. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072070-00011 · Cited by 369
Hydroxyapatite-Coated Porous Titanium for Use as an Orthopedic Biologic Attachment System
Cook, S. D., THOMAS, K. A., Kay, J. F., & Jarcho, M. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198805000-00038 · Cited by 226
Failed innovation in total hip replacement: Diagnosis and proposals for a cure
Huiskes, R. (1993) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679308994602 · Cited by 215
Ryd, L. (1986) · PubMed · Cited by 193
Self-citationBone cement improved by vacuum mixing and chilling
Lidgren, L., Bodelind, B., & Möller, J. (1987) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678709146338 · Cited by 112
Trabecular Bone Strength at the Knee
Hvid, I. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198802000-00025 · Cited by 102
Porous Coated Anatomic Tricompartmental Tibia1 Components
Ryd, L., Lindstrand, A., Stenström, A., & Selvik, G. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199002000-00032 · Cited by 66
Self-citation
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
The pathology of total joint arthroplasty
Bauer, T. W., & Schils, J. (1999) · Skeletal Radiology · doi:10.1007/s002560050552 · Cited by 367
Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty
Sochart, D. H. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199906000-00018 · Cited by 272
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Metadata
- Authors
- Ryd, L., Albrektsson, B., Carlsson, L., Dansgard, F., Herberts, P., Lindstrand, A., Regner, L., & Toksvig-Larsen, S.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1995-05
- Volume
- 77-B
- Issue
- 3
- Pages
- 377-383
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2188602644
- Cited by
- 603
- References
- 11
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.