Mutual associations among microstructural, physical and mechanical properties of human cancellous bone
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Previous studies have shown that low-density, rod-like trabecular structures develop in regions of low stress, whereas high-density, plate-like trabecular structures are found in regions of high stress. This phenomenon suggests that there may be a close relationship between the type of trabecular structure and mechanical properties. In this study, 160 cancellous bone specimens were produced from 40 normal human tibiae aged from 16 to 85 years at post-mortem. The specimens underwent micro-CT and the microstructural properties were calculated using unbiased three-dimensional methods. The specimens were tested to determine the mechanical properties and the physical/compositional properties were evaluated. The type of structure together with anisotropy correlated well with Young’s modulus of human tibial cancellous bone. The plate-like structure reflected high mechanical stress and the rod-like structure low mechanical stress. There was a strong correlation between the type of trabecular structure and the bone-volume fraction. The most effective microstructural properties for predicting the mechanical properties of cancellous bone seem to differ with age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 1×
“8.(28) Our result of the correlation between Young’s modulus and density was at the lower end but still within the normal expected range.”
BackgroundKabel, J., van Rietbergen, B., Odgaard, A., & Huiskes, R. (1999) · Bone · doi:10.1016/s8756-3282(99)00190-8 · Cited by 206
Self-citationAge‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186
Self-citation
Cited by
Cheng, A., Humayun, A., Cohen, D. J., Boyan, B. D., & Schwartz, Z. (2014) · Biofabrication · doi:10.1088/1758-5082/6/4/045007 · Cited by 265
Hunter, D. J., Gerstenfeld, L., Bishop, G., Davis, A. D., Mason, Z. D., Einhorn, T. A., Maciewicz, R. A., Newham, P., Foster, M., Jackson, S., et al. (2009) · Arthritis Research & Therapy · doi:10.1186/ar2601 · Cited by 214
“Studies on the microstructural and mechanical properties of tibial cancellous bone by Ding and colleagues have revealed that the SMI and the bone volume fraction can be primary determinants of cancellous bone mechanical properties [34].”
BackgroundAge‐related variations in the microstructure of human tibial cancellous bone
Ding, M., Odgaard, A., Linde, F., & Hvid, I. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00132-2 · Cited by 186
Self-citationDing, M., Odgaard, A., Hvid, I., & Hvid, I. (2003) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.85b6.12595 · Cited by 177
Self-citation
Metadata
- Authors
- Ding, M., Odgaard, A., Danielsen, C. C., & Hvid, I.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2002-08
- Volume
- 84-B
- Issue
- 6
- Pages
- 900-907
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2147622753
- Cited by
- 110
- References
- 3
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.