The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty
Open accessAbstract
Aims: The aim of this study was to compare the post-operative radiographic and clinical outcomes between kinematically and mechanically aligned total knee arthroplasties (TKAs). Patients and Methods: A total of 60 TKAs (30 kinematically and 30 mechanically aligned) were performed in 60 patients with varus osteoarthritis of the knee using a navigation system. The angles of orientation of the joint line in relation to the floor, the conventional and true mechanical axis (tMA) (the line from the centre of the hip to the lowest point of the calcaneus) were compared, one year post-operatively, on single-leg and double-leg standing long leg radiographs between the groups. The range of movement and 2011 Knee Society Scores were also compared between the groups at that time. Results: The angles of orientation of the joint line in the kinematic group changed from slight varus on double-leg standing to slight valgus with single-leg standing. The mechanical axes in the kinematic group passed through a neutral position of the knee in the true condition when the calcaneus was considered. The post-operative angles of flexion and functional activity scores were significantly better in the kinematic than in the mechanical group (p < 0.003 and 0.03, respectively). Conclusion: A kinematically aligned TKA results in a joint line which has a more parallel orientation in relation to the floor during single- and double-leg standing, and more neutral weight-bearing in tMA than a mechanically aligned TKA. Cite this article: Bone Joint J 2017;99-B:640–6.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical power analyses using G∗Power 3.1: tests for correlation and regression analyses
Faul, F., Erdfelder, E., Buchner, A., & Lang, A.-G. (2009) · Behavior Research Methods · doi:10.3758/brm.41.4.1149 · Cited by 37,615
Cited by
Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
Howell, S. M., Shelton, T. J., & Hull, M. L. (2018) · The Journal of Arthroplasty · doi:10.1016/j.arth.2018.07.020 · Cited by 302
Blakeney, W., Clément, J., Desmeules, F., Hagemeister, N., Rivière, C., & Vendittoli, P. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5174-1 · Cited by 198
Metadata
- Authors
- Matsumoto, T., Takayama, K., Ishida, K., Hayashi, S., Hashimoto, S., & Kuroda, R.
- Venue
- The Bone & Joint Journal
- Published
- 2017-05
- Volume
- 99-B
- Issue
- 5
- Pages
- 640-646
- ISSN
- 2049-4394 (ISSN-L)
- 2049-4408
- OpenAlex
- W2610119743
- Cited by
- 180
- References
- 3
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. https://app.cochat.ai/papers/10.1302/0301-620x.99b5.bjj-2016-0688.r2
- The paper
- Matsumoto, T., Takayama, K., Ishida, K., Hayashi, S., Hashimoto, S., & Kuroda, R. (2017). Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. The Bone & Joint Journal. https://doi.org/10.1302/0301-620x.99b5.bjj-2016-0688.r2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.