The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
Abstract
BACKGROUND Alignment in the varus or valgus outlier range of the tibial component, knee, and limb might adversely affect the long-term results of kinematically aligned total knee arthroplasty (TKA) particularly when patients are selected without restricting the degree of preoperative varus-valgus and flexion deformity. METHODS A retrospective review of all patients treated in 2007 with a primary TKA determined the 10-year implant survivorship, yearly revision rate, Oxford Knee Score, and WOMAC. All 222 knees (217 patients) were aligned kinematically using patient-specific instrumentation without restricting the degree of preoperative deformity and with the restoration of the native joint lines and limb alignment. Mechanical alignment criteria categorized the alignments of the tibial component, knee, and limb as in-range or in a varus or valgus outlier range. RESULTS The implant survivorship (yearly revision rate) was 97.5% (0.3%) for revision for any reason and 98.4% (0.2%) for aseptic failure. The percentage postoperatively aligned in the varus outlier (valgus outlier) range was 78% (0%) for the angle between the tibial component and mechanical axis of the tibia, 31% (5%) for the tibiofemoral angle of the knee according to the criteria by Ritter et al, and 7% (21%) for the hip-knee-ankle angle of the limb according to the criteria by Parratte et al. Patients grouped in the varus outlier range, valgus outlier range, and in-range had similar implant survival and function scores. The 10-year Oxford Knee Score (48 best) and WOMAC (0 best) averaged 43 and 7 points, respectively. CONCLUSION With the limitation that a large case series unlikely represents the full range of preoperative deformities and native alignments, treatment of patients with kinematically aligned TKA with patient-specific instrumentation without restricting the preoperative deformity did not adversely affect the 10-year implant survival, yearly revision rate, and level of function. LEVEL OF EVIDENCE Level III, therapeutic study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Structure of Scientific Revolutions
Kuhn, T. S., & Schlegel, R. (1963) · Physics Today · doi:10.1063/1.3050879 · Cited by 35,538
The Structure of Scientific Revolutions: 50th Anniversary Edition
Kuhn, T. S., & Hacking, I. (2012) · doi:10.7208/chicago/9780226458144.001.0001 · Cited by 21,170
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
The Effect of Alignment and BMI on Failure of Total Knee Replacement
Ritter, M. A., Davis, K. E., Meding, J. B., Pierson, J. L., Berend, M. E., & Malinzak, R. A. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00772 · Cited by 669
The Axes of Rotation of the Knee
HOLLISTER, A. M., JATANA, S., SINGH, A. K., SULLIVAN, W. W., & LUPICHUK, A. G. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199305000-00033 · Cited by 502
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Self-citationDossett, H. G., Estrada, N. A., Swartz, G. J., LeFevre, G. W., & Kwasman, B. G. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b7.32812 · Cited by 431
Howell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2621-x · Cited by 366
Self-citationPatient dissatisfaction following total knee replacement: a growing concern?
Nam, D., Nunley, R. M., & Barrack, R. L. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b11.34152 · Cited by 364
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Cited by
Inverse Kinematic Alignment for Total Knee Arthroplasty
Winnock de Grave, P., Kellens, J., Luyckx, T., Tampere, T., Lacaze, F., & Claeys, K. (2022) · Orthopaedics & Traumatology: Surgery & Research · doi:10.1016/j.otsr.2022.103305 · Cited by 82
Orsi, A. D., Wakelin, E., Plaskos, C., McMahon, S., & Coffey, S. (2023) · Arthroplasty Today · doi:10.1016/j.artd.2022.101090 · Cited by 30
Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument
Kim, K.-K., Howell, S. M., & Won, Y.-Y. (2020) · Yonsei Medical Journal · doi:10.3349/ymj.2020.61.3.201 · Cited by 23
Self-citationUse the Right Looking Glass When You Do Caliper-verified Kinematically Aligned TKA!
Howell, S. M. (2022) · Arthroplasty Today · doi:10.1016/j.artd.2022.04.003 · Cited by 2
Self-citation
Metadata
- Authors
- Howell, S. M., Shelton, T. J., & Hull, M. L.
- Venue
- The Journal of Arthroplasty
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 33
- Issue
- 12
- Pages
- 3678-3684
- ISSN
- 0883-5403 (ISSN-L)
- OpenAlex
- W2885823627
- Cited by
- 302
- References
- 44
- FWCI
- 22.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty. https://app.cochat.ai/papers/10.1016/j.arth.2018.07.020
- The paper
- Howell, S. M., Shelton, T. J., & Hull, M. L. (2018). Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2018.07.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.