The DOI matches its Crossref record.
Which mesh for hernia repair?
Open accessAbstract
INTRODUCTION: The concept of using a mesh to repair hernias was introduced over 50 years ago. Mesh repair is now standard in most countries and widely accepted as superior to primary suture repair. As a result, there has been a rapid growth in the variety of meshes available and choosing the appropriate one can be difficult. This article outlines the general properties of meshes and factors to be considered when selecting one. MATERIALS AND METHODS: We performed a search of the medical literature from 1950 to 1 May 2009, as indexed by Medline, using the PubMed search engine (< http://www.pubmed.gov >). To capture all potentially relevant articles with the highest degree of sensitivity, the search terms were intentionally broad. We used the following terms: ‘mesh, pore size, strength, recurrence, complications, lightweight, properties’. We also hand-searched the bibliographies of relevant articles and product literature to identify additional pertinent reports. RESULTS AND CONCLUSIONS: The most important properties of meshes were found to be the type of filament, tensile strength and porosity. These determine the weight of the mesh and its biocompatibility. The tensile strength required is much less than originally presumed and light-weight meshes are thought to be superior due to their increased flexibility and reduction in discomfort. Large pores are also associated with a reduced risk of infection and shrinkage. For meshes placed in the peritoneal cavity, consideration should also be given to the risk of adhesion formation. A variety of composite meshes have been promoted to address this, but none appears superior to the others. Finally, biomaterials such as acellular dermis have a place for use in infected fields but have yet to prove their worth in routine hernia repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“properties that have been shown to allow for penetration of macrophages, fibroblasts, collagen, and blood vessels [4].”
From “Long-term outcomes of ventral hernia repair using heavyweight non-woven polypropylene mesh” (2026) · cites this paper as [4]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parmaksiz, M., Dogan, A., Odabas, S., Elçin, A. E., & Elçin, Y. M. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/2/022003 · Cited by 268
Characterizing the ex vivo mechanical properties of synthetic polypropylene surgical mesh
Li, X., Kruger, J. A., Jor, J. W. Y., Wong, V., Dietz, H. P., Nash, M. P., & Nielsen, P. M. F. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.05.005 · Cited by 68
“Long-term outcomes of ventral hernia repair using heavyweight non-woven polypropylene mesh”
Risser, K. M., Schmidt, E. M., Woo, K. P., Beffa, L. R. A., Prabhu, A. S., Krpata, D. M., Rosen, M. J., Petro, C. C., & Miller, B. T. (2026) · Hernia · doi:10.1007/s10029-026-03597-8 · Cited by 2
Metadata
- Authors
- Brown, C., & Finch, J.
- Venue
- The Annals of The Royal College of Surgeons of England
- Publisher
- Royal College of Surgeons of England
- Published
- 2010-05
- Volume
- 92
- Issue
- 4
- Pages
- 272-278
- ISSN
- 0035-8843 (ISSN-L)
- 1478-7083
- OpenAlex
- W1995415995
- Cited by
- 386
- References
- 0
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.