CoChat

Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing

Gosselin, Robert C., Janatpour, Kim, Larkin, Edward C., Lee, Yanlap P., Owings, John T. · 2004 · American Journal of Clinical Pathology
Cited by 33

The DOI matches its Crossref record.

Abstract

We sought to compare coagulation test results obtained from patients using 2 plastic blood collection tubes and the traditional glass blood collection tube. Blood specimens were obtained from 241 patients in 3.2% buffered sodium citrate using standard glass tubes, in 3.2% buffered sodium citrate in plastic tubes, and in 3.2% sodium citrate "sandwich" tubes (plastic within plastic). All samples were obtained and processed contemporaneously and tested for prothrombin time (PT) and activated partial thromboplastin time (aPTT). Residual plasma was frozen at -70 degrees C for future testing, including fibrinogen, antithrombin, plasminogen, protein C and protein S (functional and antigenic), dilute Russell viper venom time (DRVVT), ristocetin cofactor, factor XIII, D dimer, anti-Xa activity, and prothrombin fragment. Although paired t test analysis revealed statistically significant differences (P < .05) between glass and plastic for PT, aPTT, fibrinogen, protein C (functional and antigenic), functional protein S, DRVVT and confirmation method, antithrombin, and factor XIII, these differences were not considered clinically significant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1309/7v2k-p1hp-9q29-bmn2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 33

Metadata

Authors
Gosselin, R. C., Janatpour, K., Larkin, E. C., Lee, Y. P., & Owings, J. T.
Venue
American Journal of Clinical Pathology
Published
2004-12-01
Volume
122
Issue
6
Pages
843-848
ISSN
0002-9173 (ISSN-L)
OpenAlex
W2036709327
Cited by
33
References
0
FWCI
1.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing. https://app.cochat.ai/papers/10.1309/7v2k-p1hp-9q29-bmn2
The paper
Gosselin, R. C., Janatpour, K., Larkin, E. C., Lee, Y. P., & Owings, J. T. (2004). Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing. American Journal of Clinical Pathology. https://doi.org/10.1309/7v2k-p1hp-9q29-bmn2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.