Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing
The DOI matches its Crossref record.
Abstract
We sought to compare coagulation test results obtained from patients using 2 plastic blood collection tubes and the traditional glass blood collection tube. Blood specimens were obtained from 241 patients in 3.2% buffered sodium citrate using standard glass tubes, in 3.2% buffered sodium citrate in plastic tubes, and in 3.2% sodium citrate "sandwich" tubes (plastic within plastic). All samples were obtained and processed contemporaneously and tested for prothrombin time (PT) and activated partial thromboplastin time (aPTT). Residual plasma was frozen at -70 degrees C for future testing, including fibrinogen, antithrombin, plasminogen, protein C and protein S (functional and antigenic), dilute Russell viper venom time (DRVVT), ristocetin cofactor, factor XIII, D dimer, anti-Xa activity, and prothrombin fragment. Although paired t test analysis revealed statistically significant differences (P < .05) between glass and plastic for PT, aPTT, fibrinogen, protein C (functional and antigenic), functional protein S, DRVVT and confirmation method, antithrombin, and factor XIII, these differences were not considered clinically significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Pitanguiera Manguera, C. L., Sumita, N. M., Picheth, G., Guidi, G. C., & Scartezini, M. (2011) · Biochemia Medica · doi:10.11613/bm.2011.024 · Cited by 56
Elimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Effects of vigorous mixing of blood vacuum tubes on laboratory test results
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Gelati, M., Volanski, W., Boritiza, K. C., Picheth, G., & Guidi, G. C. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.10.033 · Cited by 33
Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing
Gosselin, R. C., Bowyer, A., Favaloro, E. J., Johnsen, J. M., Lippi, G., Marlar, R. A., Neeves, K., & Rollins‐Raval, M. A. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15514 · Cited by 25
Self-citation
Metadata
- Authors
- Gosselin, R. C., Janatpour, K., Larkin, E. C., Lee, Y. P., & Owings, J. T.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-01
- Volume
- 122
- Issue
- 6
- Pages
- 843-848
- ISSN
- 0002-9173 (ISSN-L)
- OpenAlex
- W2036709327
- Cited by
- 33
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing. https://app.cochat.ai/papers/10.1309/7v2k-p1hp-9q29-bmn2
- The paper
- Gosselin, R. C., Janatpour, K., Larkin, E. C., Lee, Y. P., & Owings, J. T. (2004). Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing. American Journal of Clinical Pathology. https://doi.org/10.1309/7v2k-p1hp-9q29-bmn2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.