The Influence of Rapid Onsite Evaluation on the Adequacy Rate of Fine-Needle Aspiration Cytology
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Rapid onsite evaluation (ROSE) has the potential to improve the adequacy rates of fine-needle aspiration (FNA) cytology. Studies have obtained variable results on the influence of ROSE. We conducted a systematic review and meta-analysis of studies on the influence of ROSE on FNA adequacy. We synthesized evidence across all anatomic locations. We only included studies that contained a control arm and compared cohorts with ROSE against cohorts without ROSE at a single location. We screened 2,179 studies and identified 25 studies that met our inclusion criteria. On average, ROSE improves the adequacy rate by 12%, but there was considerable variability across studies. The adequacy rate with ROSE depends on the non-ROSE adequacy rate. Sixty-five percent of the variability in the adequacy rate with ROSE was found to occur because of differences in the adequacy rate without ROSE. Studies with high non-ROSE adequacy rates showed low improvement after ROSE was implemented. Studies must account for the effect of the non-ROSE adequacy rate to determine the effect of ROSE on FNA adequacy rates.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“When combined with rapid on-site evaluation (ROSE) by a trained pathologist, FNAB provides a rapid diagnosis at the point of care, allows for triage of the sample for ancillary testing, and minimizes the risk of patient loss to follow up in low resource settings.3”
From Fine needle aspiration biopsy in low‐ and middle‐income countries (2024) · cites this paper as [3]
Citations
Cites
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Klapman, J. (2003) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(03)00246-6 · Cited by 503
Iglesias-Garcia, J., Dominguez-Munoz, E. J., Abdulkader, I., Larino-Noia, J., Eugenyeva, E., Lozano-Leon, A., & Forteza-Vila, J. (2011) · American Journal of Gastroenterology · doi:10.1038/ajg.2011.119 · Cited by 354
Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis
LeBlanc, J. K., Ciaccia, D., Al-Assi, M. T., McGrath, K., Imperiale, T., Tao, L.-C., Vallery, S., DeWitt, J., Sherman, S., & Collins, E. (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)02863-3 · Cited by 282
Sakamoto, H., Kitano, M., Komaki, T., Noda, K., Chikugo, T., Dote, K., Takeyama, Y., Das, K., Yamao, K., & Kudo, M. (2009) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2008.05636.x · Cited by 226
Ljung, B.-M., Drejet, A., Chiampi, N., Jeffrey, J., Goodson, W. H., Chew, K., Moore, D. H., & Miller, T. R. (2001) · Cancer · doi:10.1002/cncr.9040 · Cited by 206
Rapid On-Site Evaluation of Transbronchial Aspirates
Davenport, R. D. (1990) · Chest · doi:10.1378/chest.98.1.59 · Cited by 177
Redman, R., Zalaznick, H., Mazzaferri, E. L., & Massoll, N. A. (2006) · Thyroid · doi:10.1089/thy.2006.16.55 · Cited by 176
Trisolini, R., Cancellieri, A., Tinelli, C., Paioli, D., Scudeller, L., Casadei, G. P., Forti Parri, S., Livi, V., Bondi, A., Boaron, M., et al. (2011) · Chest · doi:10.1378/chest.10-1521 · Cited by 169
CT-Guided Fine-Needle Aspiration Cytology of Solitary Pulmonary Nodules*
Santambrogio, L., Nosotti, M., Bellaviti, N., Pavoni, G., Radice, F., & Caputo, V. (1997) · CHEST Journal · doi:10.1378/chest.112.2.423 · Cited by 149
Diette, G. B., White, P., Terry, P. B., Jenckes, M. W., Rosenthal, D. L., & Rubin, H. R. (2000) · CHEST Journal · doi:10.1378/chest.117.4.1186 · Cited by 130
Möller, K., Papanikolaou, I. S., Toermer, T., Delicha, E. M., Sarbia, M., Schenck, U., Koch, M., Al‐Abadi, H., Meining, A. G., Schmidt, H., et al. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2008.10.008 · Cited by 117
Ghofrani, M., Beckman, D., & Rimm, D. L. (2006) · Cancer · doi:10.1002/cncr.21715 · Cited by 115
O'Malley, M. E., Weir, M. M., Hahn, P. F., Misdraji, J., Wood, B. J., & Müeller, P. R. (2002) · Radiology · doi:10.1148/radiol.2222010201 · Cited by 114
Choi, S. H., Han, K., Yoon, J. H., Moon, H. J., Son, E. J., Youk, J. H., Kim, E., & Kwak, J. Y. (2011) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2011.04011.x · Cited by 105
How important is on‐site adequacy assessment for thyroid FNA? An evaluation of 883 cases
Zhu, W., & Michael, C. W. (2007) · Diagnostic Cytopathology · doi:10.1002/dc.20552 · Cited by 93
Yarmus, L. B., der Kloot, T. E. V., Lechtzin, N., Napier, M., Dressel, D. M., & Feller-Kopman, D. J. (2011) · Journal of Bronchology & Interventional Pulmonology · doi:10.1097/lbr.0b013e31821707ee · Cited by 78
A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles
Imazu, H., Uchiyama, Y., Kakutani, H., Ikeda, K., Sumiyama, K., Kaise, M., Omar, S., Ang, T. L., & Tajiri, H. (2009) · Gastroenterology Research and Practice · doi:10.1155/2009/546390 · Cited by 70
Cleveland, P. W., Gill, K. R., Coe, S. G., Woodward, T. A., Raimondo, M., Jamil, L. H., Gross, S. A., Heckman, M. G., Crook, J. E., & Wallace, M. B. (2010) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2010.01.029 · Cited by 62
Effectiveness of Toyota Process Redesign in Reducing Thyroid Gland Fine-Needle Aspiration Error
Raab, S. S., Grzybicki, D. M., Sudilovsky, D., Balassanian, R., Janosky, J. E., & Vrbin, C. M. (2006) · American Journal of Clinical Pathology · doi:10.1309/njq1-l7ka-10uk-v93q · Cited by 60
Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer
Iglesias‐García, J., Noia, J. L., & Domínguez‐Muñoz, J. E. (2009) · Revista Española de Enfermedades Digestivas · doi:10.4321/s1130-01082009000900006 · Cited by 47
Saleh, H. A., & Khatib, G. (1996) · Acta Cytologica · doi:10.1159/000333985 · Cited by 43
Endoscopic Ultrasound in the Diagnosis and Staging of Pancreatic Cancer
Gonçalves, B. M., Soares, J., & Bastos, P. (2015) · GE Portuguese Journal of Gastroenterology · doi:10.1016/j.jpge.2015.04.007 · Cited by 41
Kucuk, C. U., Yılmaz, A., Avcı, A. Y., & Akkaya, E. (2004) · Respirology · doi:10.1111/j.1440-1843.2004.00607.x · Cited by 40
Jing, X., Michael, C. W., & Pu, R. T. (2008) · Diagnostic Cytopathology · doi:10.1002/dc.20762 · Cited by 40
Eisele, D. W., Koch, W. M., Richtsmeier, W. J., Sherman, M. E., Wu, A. Y., & Erozan, Y. S. (1992) · The Laryngoscope · doi:10.1288/00005537-199212000-00002 · Cited by 40
The Value of Immediate Cytologic Evaluation for Needle Aspiration Lung Biopsy
Padhani, A. R., Scott, W. W., CHEEMA, M., Kearney, D., & Erozan, Y. S. (1997) · Investigative Radiology · doi:10.1097/00004424-199708000-00004 · Cited by 33
Dray, M. S., Mayall, F. G., & Darlington, A. (2000) · Cytopathology · doi:10.1046/j.1365-2303.2000.00216.x · Cited by 29
Akalin, A., Lü, D., Woda, B. A., Moss, L., & Fischer, A. H. (2008) · Diagnostic Cytopathology · doi:10.1002/dc.20846 · Cited by 29
Ultrasound‐guided needle aspiration: Impact of immediate cytologic review
Moberly, A. C., Vural, E. A., Nahas, B., Bergeson, T. R., & Kokoska, M. S. (2010) · The Laryngoscope · doi:10.1002/lary.21061 · Cited by 22
CT-Guided Biopsy of Bone and Soft-Tissue Lesions: Role of On-Site Immediate Cytologic Evaluation
Virayavanich, W., Ringler, M. D., Chin, C. T., Baum, T. H., Giaconi, J. C., O’Donnell, R. J., Horvai, A., Jones, K. D., & Link, T. M. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.03.019 · Cited by 21
Improved Breast Cytology Results with Near Patient FNA Diagnosis
Hamill, J., Campbell, I., Mayall, F. G., Bartlett, A. S. J. R., & Darlington, A. (2002) · Acta Cytologica · doi:10.1159/000326710 · Cited by 21
Efficacy of On-Site Specimen Adequacy Evaluation of Image-Guided Fine and Core Needle Biopsies
Azabdaftari, G., Goldberg, N. S., & Wang, H. H. (2010) · Acta Cytologica · doi:10.1159/000324997 · Cited by 16
Endoscopic Ultrasound-Guided Fine Needle Aspiration of Pancreatic Masses in a Veteran Population
Siddiqui, A. A., Lyles, T. E., Avula, H., & Davila, R. (2010) · Pancreas · doi:10.1097/mpa.0b013e3181c5c597 · Cited by 12
Methods Specification for Diagnostic Test Accuracy Studies in Fine-Needle Aspiration Cytology
Schmidt, R. L., Factor, R. E., Affolter, K. E., Cook, J. B., Hall, B. J., Narra, K. K., Witt, B. L., Wilson, A. R., & Layfield, L. J. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcpqx1kbj2pzjfk · Cited by 11
Self-citationOn-site adequacy assessments for image-directed fine needle aspirations: a study of 341 cases.
Mf, L., Cellura, K., Schofield, K., & Mitra, A. (1995) · PubMed · Cited by 7
Endoscopic ultrasound-guided fine-needle aspiration using 22- and 25-gauge needles alternately
Iqbal, S., Mir, R. N., & Sohn, W. I. (2009) · Endoscopy · doi:10.1055/s-0028-1103444 · Cited by 4
Jamil, L. H., Jones, A., Khoór, A., Pascual, J. M., Johnson, M. M., Biewend, M. L., Crook, J. E., Woodward, T. A., Raimondo, M., & Wallace, M. B. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.03.958 · Cited by 1
Research works printed but not linked: 2
- Deeks, 2009, Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy, Version 1.0.0
- Parikh, 2009, Effectiveness of ultrasoundguided thyroid FNA with on-site pathology, Thyroid, 19, S41
Cited by
The 2021 WHO Classification of Lung Tumors: Impact of Advances Since 2015
Nicholson, A. G., Tsao, M. S., Beasley, M. B., Borczuk, A. C., Brambilla, E., Cooper, W. A., Dacic, S., Jain, D., Kerr, K. M., Lantuejoul, S., et al. (2022) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2021.11.003 · Cited by 1,554
Lung cancer organoids analyzed on microwell arrays predict drug responses of patients within a week
Hu, Y., Sui, X., Song, F., Li, Y., Li, K., Chen, Z., Yang, F., Chen, X., Zhang, Y., Wang, X., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22676-1 · Cited by 272
Trisolini, R., Cancellieri, A., Tinelli, C., de Biase, D., Valentini, I., Casadei, G. P., Paioli, D., Ferrari, F., Gordini, G., Patelli, M., et al. (2015) · CHEST Journal · doi:10.1378/chest.15-0583 · Cited by 153
Matynia, A. P., Schmidt, R. L., Barraza, G., Layfield, L. J., Siddiqui, A. A., & Adler, D. G. (2013) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.12431 · Cited by 144
Self-citationVanderLaan, P. A., Wang, H. H., Majid, A., & Folch, E. E. (2014) · Cancer Cytopathology · doi:10.1002/cncy.21431 · Cited by 108
Metadata
- Authors
- Schmidt, R. L., Witt, B. L., Lopez-Calderon, L. E., & Layfield, L. J.
- Affiliations
- University of Utah (US)
- Corresponding author
- Schmidt, Robert L.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-03-01
- Volume
- 139
- Issue
- 3
- Pages
- 300-308
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2149314016
- Semantic Scholar
- 7e433632e13e8a4ffe168a53da2ee62de3154549
- Cited by
- 149
- References
- 39
- Citations by year
- 2026: 13 · 2025: 10 · 2024: 10 · 2023: 8 · 2022: 8 · 2021: 17 · 2020: 8 · 2019: 11 · 2018: 14 · 2017: 11 · 2016: 13 · 2015: 14 · 2014: 5 · 2013: 7
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Clinical Pathology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Pathology and Forensic Medicine › Breast Lesions and Carcinomas
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- rapid on-site evaluation, fine needle aspiration cytology, anatomical location
- MeSH terms
- Humans, Quality Assurance, Health Care, Biopsy, Fine-Needle
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.