Clinical Validation of KRAS, BRAF, and EGFR Mutation Detection Using Next-Generation Sequencing

Open access
Lin, Ming-Tseh, Mosier, Stacy L., Thiess, Michele, Beierl, Katie F., Debeljak, Marija, Tseng, Li-Hui, Chen, Guoli, Yegnasubramanian, Srinivasan, Ho, Hao, Cope, Leslie, Wheelan, Sarah J., Gocke, Christopher D., Eshleman, James R. · 2014 · American Journal of Clinical Pathology
Cited by 153

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To validate next-generation sequencing (NGS) technology for clinical diagnosis and to determine appropriate read depth. METHODS: We validated the KRAS, BRAF, and EGFR genes within the Ion AmpliSeq Cancer Hotspot Panel using the Ion Torrent Personal Genome Machine (Life Technologies, Carlsbad, CA). RESULTS: We developed a statistical model to determine the read depth needed for a given percent tumor cellularity and number of functional genomes. Bottlenecking can result from too few input genomes. By using 16 formalin-fixed, paraffin-embedded (FFPE) cancer-free specimens and 118 cancer specimens with known mutation status, we validated the six traditional analytic performance characteristics recommended by the Next-Generation Sequencing: Standardization of Clinical Testing Working Group. Baseline noise is consistent with spontaneous and FFPE-induced C:G→T:A deamination mutations. CONCLUSIONS: Redundant bioinformatic pipelines are essential, since a single analysis pipeline gave false-negative and false-positive results. NGS is sufficiently robust for the clinical detection of gene mutations, with attention to potential artifacts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1309/ajcpmwgwgo34egod

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 153

Metadata

Authors
Lin, M.-T., Mosier, S. L., Thiess, M., Beierl, K. F., Debeljak, M., Tseng, L.-H., Chen, G., Yegnasubramanian, S., Ho, H., Cope, L., Wheelan, S. J., Gocke, C. D., & Eshleman, J. R.
Venue
American Journal of Clinical Pathology
Published
2014-06-01
Volume
141
Issue
6
Pages
856-866
ISSN
  • 0002-9173 (ISSN-L)
  • 1943-7722
OpenAlex
W2079913459
Cited by
153
References
10
FWCI
6.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Validation of KRAS, BRAF, and EGFR Mutation Detection Using Next-Generation Sequencing. https://app.cochat.ai/papers/10.1309/ajcpmwgwgo34egod
The paper
Lin, M.-T., Mosier, S. L., Thiess, M., Beierl, K. F., Debeljak, M., Tseng, L.-H., Chen, G., Yegnasubramanian, S., Ho, H., Cope, L., Wheelan, S. J., Gocke, C. D., & Eshleman, J. R. (2014). Clinical Validation of KRAS, BRAF, and EGFR Mutation Detection Using Next-Generation Sequencing. American Journal of Clinical Pathology. https://doi.org/10.1309/ajcpmwgwgo34egod

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.