The New Era of Automated Immunoassay
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Use of immunoassays and other ligand-binding assays in clinical diagnosis has increased dramatically during the last several years. Despite impressive technical advances, "mass production" of these assays in a routine laboratory still presents many difficulties. This review of ligand-binding assay technology highlights some recent developments, emphasizing challenges and possible solutions for cost-effective patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Replacing the complementarity-determining regions in a human antibody with those from a mouse
Jones, P. T., Dear, P. H., Foote, J., Neuberger, M. S., & Winter, G. (1986) · Nature · doi:10.1038/321522a0 · Cited by 1,406
The Use and Misuse of the Sensitive Thyrotropin Assays
NICOLOFF, J. T., & SPENCER, C. A. (1990) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-71-3-553 · Cited by 197
Cited by
Single-Layer MoS2-Based Nanoprobes for Homogeneous Detection of Biomolecules
Zhu, C., Zeng, Z., Li, H., Li, F., Fan, C., & Zhang, H. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4019572 · Cited by 1,058
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Immunosensors—principles and applications to clinical chemistry
Luppa, P. B., Sokoll, L. J., & Chan, D. W. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00629-5 · Cited by 741
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Wilson, D. H., Rissin, D. M., Kan, C. W., Fournier, D. R., Piech, T., Campbell, T. G., Meyer, R. E., Fishburn, M. W., Cabrera, C., Patel, P. P., et al. (2016) · SLAS Technology · doi:10.1177/2211068215589580 · Cited by 470
Metadata
- Authors
- Bock, J. L.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-05-01
- Volume
- 113
- Issue
- 5
- Pages
- 628-646
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2157107967
- Cited by
- 90
- References
- 3
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The New Era of Automated Immunoassay. https://app.cochat.ai/papers/10.1309/dudm-3y6l-3r1l-qp15
- The paper
- Bock, J. L. (2000). The New Era of Automated Immunoassay. American Journal of Clinical Pathology. https://doi.org/10.1309/dudm-3y6l-3r1l-qp15
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.