Earlier Detection of Myocardial Injury in a Preliminary Evaluation Using a New Troponin I Assay With Improved Sensitivity
Open accessAbstract
Cardiac troponins are important biochemical markers for defining the presence of myocardial injury. However, limitations in troponin testing exist, including the relatively late increase in troponin after onset of ischemia. We therefore evaluated a more sensitive troponin assay for detection of myocardial injury in "early presenters." Discarded serial specimens were obtained from 103 patients who had a negative cardiac troponin I (cTnI) result followed by a positive cTnI result. Results were obtained using our current cTnI method and a new more sensitive assay, TnI-Ultra (Siemens Medical Solutions, Diagnostics Division, Tarrytown, NY). Medical records were reviewed to determine the clinical diagnosis. Precision studies yielded a 10% coefficient of variation at the diagnostic cut points for cTnI (0.10 ng/mL [0.10 microg/L]) and TnI-Ultra (0.04 ng/mL [0.04 microg/L]). TnI-Ultra was positive before cTnI in 66 (64.1%) of 103 cases. We conclude that the more sensitive assay, TnI-Ultra, has better analytic performance and has the potential to detect myocardial injury earlier than the current cTnI assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Cited by
Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687
Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction
Keller, T., Zeller, T., Peetz, D., Tzikas, S., Roth, A., Czyz, E., Bickel, C., Baldus, S., Warnholtz, A., Fröhlich, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0903515 · Cited by 1,150
Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,084
Recommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Troponin elevation in coronary vs. non-coronary disease
Agewall, S., Giannitsis, E., Jernberg, T., & Katus, H. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq456 · Cited by 592
Metadata
- Authors
- Melanson, S. E. F., Morrow, D. A., & Jarolim, P.
- Venue
- American Journal of Clinical Pathology
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-08
- Volume
- 128
- Issue
- 2
- Pages
- 282-286
- ISSN
- 0002-9173 (ISSN-L)
- 1943-7722
- OpenAlex
- W2035285369
- Cited by
- 210
- References
- 1
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Earlier Detection of Myocardial Injury in a Preliminary Evaluation Using a New Troponin I Assay With Improved Sensitivity. https://app.cochat.ai/papers/10.1309/q9w5hjtt24gqcxxx
- The paper
- Melanson, S. E. F., Morrow, D. A., & Jarolim, P. (2007). Earlier Detection of Myocardial Injury in a Preliminary Evaluation Using a New Troponin I Assay With Improved Sensitivity. American Journal of Clinical Pathology. https://doi.org/10.1309/q9w5hjtt24gqcxxx
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.