Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report)
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Over the last 30 years, IUPAC published several documents with the goal of achieving standardized nomenclature and methodology for potentiometric ion-selective electrodes (ISEs). The ISE vocabulary was formulated, measurement protocols were suggested, and the selectivity coefficients were compiled. However, in light of new discoveries and experimental possibilities in the field of ISEs, some of the IUPAC recommendations have become outdated. The goal of this technical report is to direct attention to ISE practices and the striking need for updated or refined IUPAC recommendations which are consistent with the state of the art of using macro- and microfabricated planar microelectrodes. Some of these ISE practices have never been addressed by IUPAC but have gained importance with the technological and theoretical developments of recent years. In spite of its recognized importance, a generally acceptable revision of the current IUPAC recommendations is far beyond the scope of this work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Recommendations for nomenclature of ionselective electrodes (IUPAC Recommendations 1994)
Buck, R. P., & Lindner, E. (1994) · Pure and Applied Chemistry · doi:10.1351/pac199466122527 · Cited by 1,586
Self-citationUmezawa, Y., Bühlmann, P., Umezawa, K., Tohda, K., & Amemiya, S. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072101851 · Cited by 1,099
Self-citationRecommendations for Nomenclature of ION-Selective Electrodes
(1976) · Pure and Applied Chemistry · doi:10.1351/pac197648010127 · Cited by 696
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
The Principles of Ion-Selective Electrodes and of Membrane Transport
(1981) · Studies in Analytical Chemistry · doi:10.1016/c2009-0-14175-2 · Cited by 650
Measurement of pH. Definition, standards, and procedures (IUPAC Recommendations 2002)
Buck, R. P., Rondinini, S., Covington, A. K., Baucke, F. G. K., Brett, C. M. A., Camoes, M. F., Milton, M. J. T., Mussini, T., Naumann, R., Pratt, K. W., et al. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274112169 · Cited by 519
Fibbioli, M., Morf, W. E., Badertscher, M., de Rooij, N. F., & Pretsch, E. (2000) · Electroanalysis · doi:10.1002/1521-4109(200011)12:16<1286::aid-elan1286>3.0.co;2-q · Cited by 443
Cadogan, A., Gao, Z., Lewenstam, A., Ivaska, A., & Diamond, D. (1992) · Analytical Chemistry · doi:10.1021/ac00045a007 · Cited by 428
Coated wire ion-selective electrodes
Cattrall, R. W., & Freiser, H. (1971) · Analytical Chemistry · doi:10.1021/ac60307a032 · Cited by 387
Cited by
Rational design of all-solid-state ion-selective electrodes and reference electrodes
Hu, J., Stein, A., & Bühlmann, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.004 · Cited by 586
Privett, B. J., Shin, J. H., & Schoenfisch, M. H. (2010) · Analytical Chemistry · doi:10.1021/ac101075n · Cited by 334
Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes
Lindner, E., & Gyurcsányi, R. E. (2009) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-008-0608-1 · Cited by 320
Self-citation
Metadata
- Authors
- Lindner, E., & Umezawa, Y.
- Venue
- Pure and Applied Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2008-01-01
- Volume
- 80
- Issue
- 1
- Pages
- 85-104
- ISSN
- 0033-4545 (ISSN-L)
- 1365-3075
- OpenAlex
- W1984373290
- Cited by
- 262
- References
- 39
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.