The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Development, Operation, and Application of the Ion-Sensitive Field-Effect Transistor as a Tool for Electrophysiology
Abstract
A new solid-state device has been developed for the measurement of ion activities in electrochemical and biological environments. One can recognize in the device the properties of both a glass electrode and a field-effect transistor. This justifies the name ion-sensitive field-effect transistor. The device makes it possible to measure ion activities without using a reference electrode. For its application, a special electronic circuit is described. Results of measured Na+and H+ion activities are given in detail. As an example for electrophysiological application, results are shown of recorded extracellular ion pulses measured with a guinea pig taenia coli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Self-citationCation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
Cited by
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Self-citationDiverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Patolsky, F., & Lieber, C. M. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00791-1 · Cited by 699
Recent advances in biologically sensitive field-effect transistors (BioFETs)
Schöning, M. J., & Poghossian, A. (2002) · The Analyst · doi:10.1039/b204444g · Cited by 566
Metadata
- Authors
- Bergveld, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1972-09
- Volume
- BME-19
- Issue
- 5
- Pages
- 342-351
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2072931302
- Cited by
- 654
- References
- 2
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development, Operation, and Application of the Ion-Sensitive Field-Effect Transistor as a Tool for Electrophysiology. https://app.cochat.ai/papers/10.1109/tbme.1972.324137
- The paper
- Bergveld, P. (1972). Development, Operation, and Application of the Ion-Sensitive Field-Effect Transistor as a Tool for Electrophysiology. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1972.324137
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.