CoChat

Prediction of Vertebral Strength In Vitro by Spinal Bone Densitometry and Calcaneal Ultrasound

Open access
Cheng, Xiao G., Nicholson, Patrick H. F., Boonen, Steven, Lowet, Geert, Brys, Peter, Aerssens, Jeroen, van der Perre, Georges, Dequeker, Jan · 1997 · Journal of Bone and Mineral Research
Cited by 144

The DOI matches its Crossref record.

Abstract

Spinal bone mineral density (BMD) measurements and calcaneal ultrasound were compared in terms of their ability to predict the strength of the third lumbar vertebral body using specimens from 62 adult cadavers (28 females, 34 males). BMD was measured using dual X-ray absorptiometry (DXA) in both vertebra and calcaneus. Quantitative computed tomography (QCT) was used to determine trabecular BMD, cortical BMD, cortical area, and total cross-sectional area (CSA) of the vertebral body. Bone velocity (BV) and broadband ultrasonic attenuation (BUA) were measured in the right calcaneus. Vertebral strength was determined by uniaxial compressive testing. Vertebral ultimate load was best correlated with DXA-determined vertebral BMD (r2 = 0.64). Of the QCT parameters, the best correlation with strength was obtained using the product of trabecular BMD and CSA (r2 = 0.61). For vertebral ultimate stress, however, the best correlation was observed with QCT-measured trabecular BMD (r2 = 0.51); the correlation with DXA-determined BMD was slightly poorer (r2 = 0.44). Calcaneal ultrasound correlated only weakly with both ultimate load and stress with correlation coefficients (r2) of 0.10–0.17, as did calcaneal BMD (r2 = 0.18). Both spinal DXA and spinal QCT were significantly (p < 0.001) better predictors of L3 ultimate load and stress than were either calcaneal ultrasound or calcaneal DXA. Multiple regression analysis revealed that calcaneal ultrasound did not significantly improve the predictive ability of either DXA or QCT for L3 ultimate load or stress. Calcaneal DXA BMD, bone velocity, and BUA correlated well with each other (r2 = 0.67–0.76), but were only modestly correlated with the DXA and QCT measurements of the vertebra. These data indicate that spinal DXA and spinal QCT provide comparable prediction of vertebral strength, but that a substantial proportion (typically 40%) of the variability in vertebral strength is unaccounted for by BMD measurements. Ultrasonic measurements at the calcaneus are poor predictors of vertebral strength in vitro, and ultrasound does not add predictive information independently of BMD. These findings contrast with emerging clinical data, suggesting that calcaneal ultrasound may be a valuable predictor of vertebral fracture risk in vivo. A possible explanation for this apparent discrepancy between in vivo and in vitro findings could be that current clinical ultrasound measurements at the calcaneus reflect factors that are related to fracture risk but not associated with bone fragility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.1997.12.10.1721

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 144

Metadata

Authors
Cheng, X. G., Nicholson, P. H. F., Boonen, S., Lowet, G., Brys, P., Aerssens, J., van der Perre, G., & Dequeker, J.
Venue
Journal of Bone and Mineral Research
Published
1997-10-01
Volume
12
Issue
10
Pages
1721-1728
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2042738993
Cited by
144
References
0
FWCI
6.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of Vertebral Strength In Vitro by Spinal Bone Densitometry and Calcaneal Ultrasound. https://app.cochat.ai/papers/10.1359/jbmr.1997.12.10.1721
The paper
Cheng, X. G., Nicholson, P. H. F., Boonen, S., Lowet, G., Brys, P., Aerssens, J., van der Perre, G., & Dequeker, J. (1997). Prediction of Vertebral Strength In Vitro by Spinal Bone Densitometry and Calcaneal Ultrasound. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1997.12.10.1721

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.