Prediction of Vertebral Strength In Vitro by Spinal Bone Densitometry and Calcaneal Ultrasound
Open accessThe DOI matches its Crossref record.
Abstract
Spinal bone mineral density (BMD) measurements and calcaneal ultrasound were compared in terms of their ability to predict the strength of the third lumbar vertebral body using specimens from 62 adult cadavers (28 females, 34 males). BMD was measured using dual X-ray absorptiometry (DXA) in both vertebra and calcaneus. Quantitative computed tomography (QCT) was used to determine trabecular BMD, cortical BMD, cortical area, and total cross-sectional area (CSA) of the vertebral body. Bone velocity (BV) and broadband ultrasonic attenuation (BUA) were measured in the right calcaneus. Vertebral strength was determined by uniaxial compressive testing. Vertebral ultimate load was best correlated with DXA-determined vertebral BMD (r2 = 0.64). Of the QCT parameters, the best correlation with strength was obtained using the product of trabecular BMD and CSA (r2 = 0.61). For vertebral ultimate stress, however, the best correlation was observed with QCT-measured trabecular BMD (r2 = 0.51); the correlation with DXA-determined BMD was slightly poorer (r2 = 0.44). Calcaneal ultrasound correlated only weakly with both ultimate load and stress with correlation coefficients (r2) of 0.10–0.17, as did calcaneal BMD (r2 = 0.18). Both spinal DXA and spinal QCT were significantly (p < 0.001) better predictors of L3 ultimate load and stress than were either calcaneal ultrasound or calcaneal DXA. Multiple regression analysis revealed that calcaneal ultrasound did not significantly improve the predictive ability of either DXA or QCT for L3 ultimate load or stress. Calcaneal DXA BMD, bone velocity, and BUA correlated well with each other (r2 = 0.67–0.76), but were only modestly correlated with the DXA and QCT measurements of the vertebra. These data indicate that spinal DXA and spinal QCT provide comparable prediction of vertebral strength, but that a substantial proportion (typically 40%) of the variability in vertebral strength is unaccounted for by BMD measurements. Ultrasonic measurements at the calcaneus are poor predictors of vertebral strength in vitro, and ultrasound does not add predictive information independently of BMD. These findings contrast with emerging clinical data, suggesting that calcaneal ultrasound may be a valuable predictor of vertebral fracture risk in vivo. A possible explanation for this apparent discrepancy between in vivo and in vitro findings could be that current clinical ultrasound measurements at the calcaneus reflect factors that are related to fracture risk but not associated with bone fragility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Quantitative Ultrasound in the Management of Osteoporosis: The 2007 ISCD Official Positions
Krieg, M.-A., Barkmann, R., Gonnelli, S., Stewart, A., Bauer, D. C., Del Rio Barquero, L., Kaufman, J. J., Lorenc, R., Miller, P. D., Olszynski, W. P., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.011 · Cited by 387
Osteoporosis: the evolution of a diagnosis
Lorentzon, M., & Cummings, S. R. (2015) · Journal of Internal Medicine · doi:10.1111/joim.12369 · Cited by 379
Keaveny, T. M., Donley, D. W., Hoffmann, P. F., Mitlak, B. H., Glass, E. V., & San Martin, J. A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061011 · Cited by 258
Is Quantitative Ultrasound Dependent on Bone Structure? A Reflection
Njeh, C. F., Fuerst, T., Diessel, E., & Genant, H. K. (2001) · Osteoporosis International · doi:10.1007/pl00020939 · Cited by 214
“Also, calcaneal QUS is not as good as lumbar BMD in predicting vertebral strength [170,171].”
Ebbesen, E. N., Thomsen, J. S., Beck-Nielsen, H., Nepper-Rasmussen, H. J., & Mosekilde, L. (1999) · Bone · doi:10.1016/s8756-3282(99)00216-1 · Cited by 187
Bolotin, H. H., & Sievänen, H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.5.799 · Cited by 185
“23), which was somewhat lower than reported by others, (28,57) but marginally higher than that reported by Bjarnason et al.”
BackgroundResultRoux, J. P., Wegrzyn, J., Boutroy, S., Bouxsein, M. L., Hans, D., & Chapurlat, R. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2316-7 · Cited by 169
“In order to simulate the X-rays' attenuation of soft tissue, a 42-mm-thick PMMA plate was used as recommended in previous ex vivo studies [1, 13].”
MethodSex Differences of Human Trabecular Bone Microstructure in Aging Are Site-Dependent
Eckstein, F., Matsuura, M., Kuhn, V., Priemel, M., Müller, R., Link, T. M., & Lochmüller, E.-M. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070301 · Cited by 161
Biomechanical consequences of an isolated overload on the human vertebral body
Kopperdahl, D. L., Pearlman, J. L., & Keaveny, T. M. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180502 · Cited by 120
Hussein, A. I., Jackman, T. M., Morgan, S. R., Barest, G. D., & Morgan, E. F. (2013) · Osteoporosis International · doi:10.1007/s00198-013-2417-3 · Cited by 39
“For example, an average BMD explains only ∼60 % of the variance in vertebral strength [5], and nearly half of the individuals who have fracture do not exhibit average BMD in the osteoporotic range [6].”
BackgroundNekkanty, S., Yerramshetty, J., Kim, D.-G., Zauel, R., Johnson, E., Cody, D. D., & Yeni, Y. N. (2010) · Bone · doi:10.1016/j.bone.2010.07.001 · Cited by 23
Metadata
- Authors
- Cheng, X. G., Nicholson, P. H. F., Boonen, S., Lowet, G., Brys, P., Aerssens, J., van der Perre, G., & Dequeker, J.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-10-01
- Volume
- 12
- Issue
- 10
- Pages
- 1721-1728
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2042738993
- Cited by
- 144
- References
- 0
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.