Quantitative Ultrasound of the Calcaneus Reflects the Mechanical Properties of Calcaneal Trabecular Bone

Open access
Bouxsein, M. L., Radloff, S. E. · 1997 · Journal of Bone and Mineral Research

Abstract

To provide new information about the potential role of quantitative ultrasound (QUS) in fracture risk prediction, we assessed whether QUS and densitometric variables derived from measurements of intact cadaveric feet were associated with the mechanical properties of calcaneal trabecular bone. We obtained 31 intact cadaveric feet from the local anatomic gifts program, including 13 men and 18 women, with a mean age of 77 years (range 50–91 years). Broadband ultrasound attenuation (BUA) and ultrasound transit velocity (SOS) were assessed in the intact cadaveric feet using a water-based ultrasound system. In addition, we measured the bone mineral density (BMD) of the posterior calcaneus using dual-energy X-ray absorptiometry. Cubes of trabecular bone were then removed from the calcaneus at approximately the same location as the QUS measurements were obtained, and the elastic modulus and ultimate strength of the trabecular bone specimens were measured by compressing them in the mediolateral direction. We found that QUS variables were moderately to strongly correlated with the mechanical properties of calcaneal trabecular bone (r2 = 0.48–0.63, p < 0.001 for all). However, the strongest associations with the mechanical properties trabecular bone were provided by calcaneus BMD and trabecular bone apparent density (r2 = 0.66–0.88). BUA and densitometric measurements were independently associated with elastic modulus, but not with ultimate strength. Our results indicate that QUS measurements of the intact heel are associated with the mechanical properties of calcaneal trabecular bone and, in some cases, provide information in addition to that provided by BMD or density measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.1997.12.5.839

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 200

Metadata

Authors
Bouxsein, M. L., & Radloff, S. E.
Venue
Journal of Bone and Mineral Research
Published
1997-05-01
Volume
12
Issue
5
Pages
839-846
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2074132390
Cited by
200
References
4
FWCI
11.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative Ultrasound of the Calcaneus Reflects the Mechanical Properties of Calcaneal Trabecular Bone. https://app.cochat.ai/papers/10.1359/jbmr.1997.12.5.839
The paper
Bouxsein, M. L., & Radloff, S. E. (1997). Quantitative Ultrasound of the Calcaneus Reflects the Mechanical Properties of Calcaneal Trabecular Bone. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1997.12.5.839

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.