CoChat

Mechanical properties of trabecular bone. Dependency on strain rate

Linde, Frank, Nørgaard, Peter, Hvid, Ivan, Odgaard, Anders, Søballe, Kjeld · 1991 · Journal of Biomechanics

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

The effect of strain rate (epsilon) and apparent density (rho) on stiffness (E), strength (sigma u), and ultimate strain (epsilon u) was studied in 60 human trabecular bone specimens from the proximal tibia. Testing was performed by uniaxial compression to 5% specimen strain. Six different strain rates were used: 0.0001, 0.001, 0.01, 0.1, 1, and 10 s-1. Apparent density ranged between 0.23 and 0.59 g cm-3. Linear and non-linear regression analyses using strength, stiffness and ultimate strain as dependent variables (Y) and strain rate and apparent density as independent variables were performed using the following models: Y = a rho b epsilon c, Y = rho b(a + c epsilon; Y = (a + b rho)epsilon c, Y = a rho 2 epsilon c, E = a rho 3 epsilon c. The variations of strength and stiffness were explained equally well by the linear and the power function relationship to strain rate. The exponent was 0.07 in the power function relationship between strength and strain rate and 0.05 between stiffness and strain rate. The variation of ultimate strain was explained best using a power function relationship to strain rate (exponent = 0.03). The variation of strength and stiffness was explained equally well by the linear, power function and quadratic relationship to apparent density. The cubic relationship between stiffness and apparent density showed a less good fit. Ultimate strain varied independently of apparent density.

Overview

Integrity signals

Registry

Crossref · 10.1016/0021-9290(91)90305-7

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Research works printed but not linked: 4

  1. Cassidy, 1985, Mechanical and architectural properties in bovine cancellous bone, Trans. ORS, 10, 354
  2. Downey, 1987, Compressive loading raises intraosseous pressure in the femoral head, Trans. ORS, 12, 496
  3. Harrigan, 1981, The influence of apparent density and trabecular orientation on the elastic modulus of cancellous bone, Trans. ORS, 6, 277
  4. McElhaney, 1970, A Porous Block Model for Cancellous Bone

Cited by

See all 218

Metadata

Authors
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K.
Affiliations
Aarhus University Hospital (DK)
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1991-01
Volume
24
Issue
9
Pages
803-809
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2143367764
Cited by
171
References
41
Citations by year
2026: 4 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 3 · 2020: 9 · 2019: 9 · 2018: 3 · 2017: 3 · 2016: 4 · 2015: 7 · 2014: 9 · 2013: 6 · 2012: 6
FWCI
3.35
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
Keywords
trabecular bone, strain rate, apparent density, stiffness, ultimate strength, ultimate strain, uniaxial compression, power function relationship, proximal tibia
MeSH terms
Aged, Biomechanical Phenomena, Bone and Bones, Epiphyses, Humans, Knee Joint, Male, Tensile Strength, Tibia, Bone Density, Weight-Bearing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical properties of trabecular bone. Dependency on strain rate. https://app.cochat.ai/papers/10.1016/0021-9290(91)90305-7
The paper
Linde, F., Nørgaard, P., Hvid, I., Odgaard, A., & Søballe, K. (1991). Mechanical properties of trabecular bone. Dependency on strain rate. Journal of Biomechanics. https://doi.org/10.1016/0021-9290(91)90305-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.