Electrophysiological Responses of Human Bone Cells to Mechanical Stimulation: Evidence for Specific Integrin Function in Mechanotransduction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Bone cells respond to mechanical stimuli, but the transduction mechanisms responsible are not fully understood. Integrins, a family of heterodimeric transmembrane glycoproteins, which link components of the extracellular matrix with the actin cytoskeleton, have been implicated as mechanoreceptors. We have assessed the roles of integrins in the transduction of cyclical mechanical stimuli to human bone cells (HBCs), which results in changes in membrane potential. HBC showed membrane depolarization following 0.104 Hz mechanical stimulation and membrane hyperpolarization following stimulation at 0.33 Hz. The membrane depolarization response involved tetrodotoxin-sensitive sodium channels and could be inhibited by antibodies against αV, β1, and β5 integrins. In contrast, the hyperpolarization response was inhibited by gadolinium and antibodies to the integrin-associated protein (CD47), α5 and β1 integrin. Both responses could be abrogated by Arg-Gly-Asp (RGD)-containing peptides, inhibition of tyrosine kinase activity, and disruption of the cytoskeleton. These results demonstrate differential electrophysiological responses of HBC to different frequencies of mechanical strain. Furthermore, they suggest that integrins act as HBC mechanoreceptors with distinct signaling pathways being activated by different frequencies of mechanical stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adhesion receptors of the immune system
Springer, T. A. (1990) · Nature · doi:10.1038/346425a0 · Cited by 6,477
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
Cited by
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
The Osteocyte: An Endocrine Cell … and More
Dallas, S. L., Prideaux, M., & Bonewald, L. F. (2013) · Endocrine Reviews · doi:10.1210/er.2012-1026 · Cited by 1,042
Mechanotransduction in bone—role of the lacunocanalicular network
Burger, E. H., & Klein‐Nulend, J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.9001.s101 · Cited by 897
Tensegrity II. How structural networks influence cellular information processing networks
Ingber, D. E. (2003) · Journal of Cell Science · doi:10.1242/jcs.00360 · Cited by 839
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Metadata
- Authors
- Salter, D. M., Robb, J. E., & Wright, M. O.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-07-01
- Volume
- 12
- Issue
- 7
- Pages
- 1133-1141
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2093509637
- Cited by
- 150
- References
- 3
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrophysiological Responses of Human Bone Cells to Mechanical Stimulation: Evidence for Specific Integrin Function in Mechanotransduction. https://app.cochat.ai/papers/10.1359/jbmr.1997.12.7.1133
- The paper
- Salter, D. M., Robb, J. E., & Wright, M. O. (1997). Electrophysiological Responses of Human Bone Cells to Mechanical Stimulation: Evidence for Specific Integrin Function in Mechanotransduction. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.1997.12.7.1133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.