Measurement of Midfemoral Shaft Geometry: Repeatability and Accuracy Using Magnetic Resonance Imaging and Dual-Energy X-ray Absorptiometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Although macroscopic geometric architecture is an important determinant of bone strength, there is limited published information relating to the validation of the techniques used in its measurement. This study describes new techniques for assessing geometry at the midfemur using magnetic resonance imaging (MRI) and dual-energy X-ray absorptiometry (DXA) and examines both the repeatability and the accuracy of these and previously described DXA methods. Contiguous transverse MRI (Philips 1.5T) scans of the middle one-third femur were made in 13 subjects, 3 subjects with osteoporosis. Midpoint values for total width (TW), cortical width (CW), total cross-sectional area (TCSA), cortical cross-sectional area (CCSA), and volumes from reconstructed three-dimensional (3D) images (total volume [TV] and cortical volume [CVol]) were derived. Midpoint TW and CW also were determined using DXA (Lunar V3.6, lumbar software) by visual and automated edge detection analysis. Repeatability was assessed on scans made on two occasions and then analyzed twice by two independent observers (blinded), with intra- and interobserver repeatability expressed as the CV (CV ± SD). Accuracy was examined by comparing MRI and DXA measurements of venison bone (and Perspex phantom for MRI), against “gold standard” measures made by vernier caliper (width), photographic image digitization (area) and water displacement (volume). Agreement between methods was analyzed using mean differences (MD ± SD%). MRI CVs ranged from 0.5 ± 0.5% (TV) to 3.1 ± 3.1% (CW) for intraobserver and 0.55 ± 0.5% (TV) to 3.6 ± 3.6% (CW) for interobserver repeatability. DXA results ranged from 1.6 ± 1.5% (TW) to 4.4 ± 4.5% (CW) for intraobserver and 3.8 ± 3.8% (TW) to 8.3 ± 8.1% (CW) for interobserver variation. MRI accuracy was excellent for TV (3.3 ± 6.4%), CVol (3.5 ± 4.0%), TCSA (1.8 ± 2.6%), and CCSA (1.6 ± 4.2%) but not TW (4.1 ± 1.4%) or CW (16.4 ± 14.9%). DXA results were TW (6.8 ± 2.7%) and CW (16.4 ± 17.0%). MRI measures of geometric parameters of the midfemur are highly accurate and repeatable, even in osteoporosis. Both MRI and DXA techniques have limited value in determining cortical width. MRI may prove valuable in the assessment of surface-specific bone accrual and resorption responses to disease, therapy, and variations in mechanical loading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Aerssens, J., Boonen, S., Lowet, G., & Dequeker, J. (1998) · Endocrinology · doi:10.1210/endo.139.2.5751 · Cited by 793 · cited 1×
“We adjusted for interspecies differences in bone composition and density between venison and human bone (25) by calculating the average volumetric BMD (vBMD) of the three bones (two scans of each bone) measured using pQCT (Norland/Stratec XCT 960 Forearm Scanner; Birkenfeld, Germany; in vitro [venison]; CV, 1.”
Method
Cited by
Bass, S. L., Saxon, L., Daly, R. M., Turner, C. H., Robling, A. G., Seeman, E., & Stuckey, S. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.12.2274 · Cited by 495
The relationship between muscle size and bone geometry during growth and in response to exercise
Daly, R. M., Saxon, L., Turner, C. H., Robling, A. G., & Bass, S. L. (2004) · Bone · doi:10.1016/j.bone.2003.11.009 · Cited by 215
Combination of bone mineral density and upper femur geometry improves the prediction of hip fracture
Pulkkinen, P., Partanen, J., Jalovaara, P., & J�ms�, T. (2004) · Osteoporosis International · doi:10.1007/s00198-003-1556-3 · Cited by 159
Whitney, D. G., Singh, H., Miller, F., Barbe, M. F., Slade, J. M., Pohlig, R. T., & Modlesky, C. M. (2017) · Bone · doi:10.1016/j.bone.2016.10.005 · Cited by 108
Effects of once-weekly oral alendronate on bone in children on glucocorticoid treatment
Rudge, S., Hailwood, S., Horne, A., Lucas, J., Wu, F., & Cundy, T. (2005) · Rheumatology · doi:10.1093/rheumatology/keh538 · Cited by 108
Metadata
- Authors
- Woodhead, H. J., Kemp, A. F., Blimkie, C. J. R., Briody, J. N., Duncan, C. S., Thompson, M., Lam, A., Howman-Giles, R., & Cowell, C. T.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-12-01
- Volume
- 16
- Issue
- 12
- Pages
- 2251-2259
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2013195869
- Cited by
- 53
- References
- 2
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Midfemoral Shaft Geometry: Repeatability and Accuracy Using Magnetic Resonance Imaging and Dual-Energy X-ray Absorptiometry. https://app.cochat.ai/papers/10.1359/jbmr.2001.16.12.2251
- The paper
- Woodhead, H. J., Kemp, A. F., Blimkie, C. J. R., Briody, J. N., Duncan, C. S., Thompson, M., Lam, A., Howman-Giles, R., & Cowell, C. T. (2001). Measurement of Midfemoral Shaft Geometry: Repeatability and Accuracy Using Magnetic Resonance Imaging and Dual-Energy X-ray Absorptiometry. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.2001.16.12.2251
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.