Radius Bone Strength in Bending, Compression, and Falling and Its Correlation With Clinical Densitometry at Multiple Sites
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study comprehensively analyzes the ability of site‐specific and nonsite‐specific clinical densitometric techniques for predicting mechanical strength of the distal radius in different loading configurations. DXA of the distal forearm, spine, femur, and total body and peripheral quantitative computed tomography (pQCT) measurements of the distal radius (4, 20, and 33%) were obtained in situ (with soft tissues) in 129 cadavers, aged 80.16 ± 9.8 years. Spinal QCT and calcaneal quantitative ultrasound (QUS) were performed ex situ in degassed specimens. The left radius was tested in three‐point bending and axial compression, and the right forearm was tested in a fall configuration, respectively. Correlation coefficients with radius DXA were r = 0.89, 0.84, and 0.70 for failure in three‐point bending, axial compression, and the fall simulation, respectively. The correlation with pQCT (r = 0.75 for multiple regression models with the fall) was not significantly higher than for DXA. Nonsite‐specific measurements and calcaneal QUS displayed significantly (p < 0.01) lower correlation coefficients, and QUS did only contribute to the prediction of axial failure stress but not of failure load. We conclude that a combination of pQCT parameters involves only marginal improvement in predicting mechanical strength of the distal radius, nonsite‐specific measurements are less accurate for this purpose, and QUS adds only little independent information to site‐specific bone mass. Therefore, the noninvasive diagnosis of loss of strength at the distal radius should rely on site‐specific measurements with DXA or pQCT and may be the earliest chance to detect individuals at risk of osteoporotic fracture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marshall, D., Johnell, O., & Wedel, H. (1996) · BMJ · doi:10.1136/bmj.312.7041.1254 · Cited by 3,709
Cited by
Hodsman, A. B., Bauer, D. C., Dempster, D. W., Dian, L., Hanley, D. A., Harris, S. T., Kendler, D. L., McClung, M. R., Miller, P. D., Olszynski, W. P., et al. (2005) · Endocrine Reviews · doi:10.1210/er.2004-0006 · Cited by 718
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Quantitative Ultrasound in the Management of Osteoporosis: The 2007 ISCD Official Positions
Krieg, M.-A., Barkmann, R., Gonnelli, S., Stewart, A., Bauer, D. C., Del Rio Barquero, L., Kaufman, J. J., Lorenc, R., Miller, P. D., Olszynski, W. P., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.011 · Cited by 387
Bone geometry and skeletal fragility
Bouxsein, M. L., & Karasik, D. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0002-9 · Cited by 165
Matsuura, M., Eckstein, F., Lochmüller, E.-M., & Zysset, P. K. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0073-7 · Cited by 117
Self-citation
Metadata
- Authors
- Lochmüller, E., Lill, C. A., Kuhn, V., Schneider, E., & Eckstein, F.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-09
- Volume
- 17
- Issue
- 9
- Pages
- 1629-1638
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2050102966
- Cited by
- 115
- References
- 1
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radius Bone Strength in Bending, Compression, and Falling and Its Correlation With Clinical Densitometry at Multiple Sites. https://app.cochat.ai/papers/10.1359/jbmr.2002.17.9.1629
- The paper
- Lochmüller, E., Lill, C. A., Kuhn, V., Schneider, E., & Eckstein, F. (2002). Radius Bone Strength in Bending, Compression, and Falling and Its Correlation With Clinical Densitometry at Multiple Sites. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.2002.17.9.1629
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.