Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur

Van Rietbergen, B, Huiskes, R, Eckstein, F, Rüegsegger, P·2003·Journal of Bone and Mineral Research

Abstract

Quantitative information about bone tissue‐level loading is essential for understanding bone mechanical behavior. We made microfinite element models of a healthy and osteoporotic human femur and found that tissue‐level strains in the osteoporotic femoral head were 70% higher on average and less uniformly distributed than those in the healthy one. Introduction: Bone tissue stresses and strains in healthy load‐adapted trabecular architectures should be distributed rather evenly, because no bone tissue is expected to be overloaded or unused. In this study, we evaluate this paradigm with the use of microfinite element (μFE) analyses to calculate tissue‐level stresses and strains for the human femur. Our objectives were to quantify the strain distribution in the healthy femur, to investigate to what extent this distribution is affected by osteoporosis, to determine if osteoporotic bone is simply bone adapted to lower load levels, and to determine the “safety factor” for trabecular bone. Materials and Methods: μFE models of a healthy and osteoporotic proximal femur were made from microcomputed tomography images. The models consisted of over 96 and 71 million elements for the healthy and osteoporotic femur, respectively, and represented their internal and external morphology in detail. Stresses and strains were calculated for each element and their distributions were calculated for a volume of interest (VOI) of trabecular bone in the femoral head. Results: The average tissue‐level principal strain magnitude in the healthy VOI was 304 ± 185 microstrains and that in the osteoporotic VOI was 520 ± 355 microstrains. Calculated safety factors were 8.6 for the healthy and 4.9 for the osteoporotic femurs. After reducing the force applied to the osteoporotic model to 59%, the average strain compared with that of the healthy femur, but the SD was larger (208 microstrains). Conclusions: Strain magnitudes in the osteoporotic bone were much higher and less uniformly distributed than those in the healthy one. After simulated joint‐load reduction, strain magnitudes in the osteoporotic femur were very similar to those in the healthy one, but their distribution is still wider and thus less favorable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1359/jbmr.2003.18.10.1781

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 256

Metadata

Authors
Van Rietbergen, B., Huiskes, R., Eckstein, F., & Rüegsegger, P.
Venue
Journal of Bone and Mineral Research
Published
2003-10
Volume
18
Issue
10
Pages
1781-1788
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2144424358
Cited by
256
References
18
FWCI
12.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur. https://app.cochat.ai/papers/10.1359/jbmr.2003.18.10.1781
The paper
Van Rietbergen, B., Huiskes, R., Eckstein, F., & Rüegsegger, P. (2003). Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur. Journal of Bone and Mineral Research. https://doi.org/10.1359/jbmr.2003.18.10.1781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.