The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of a Gaussian laser beam diameter through the direct inversion of knife-edge data
Abstract
An inversion algorithm, involving a linear least-squares method, is developed to analyze the intensity data obtained by application of the traveling knife-edge method. Through use of simulated intensity data, diameters can be measured to an accuracy of 0.05%. The method also yields good results when it is applied to He–Ne laser beam data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technique for Fast Measurement of Gaussian Laser Beam Parameters
Arnaud, J. A., Hubbard, W. M., Mandeville, G. D., de la Clavière, B., Franke, E. A., & Franke, J. M. (1971) · Applied Optics · doi:10.1364/ao.10.002775 · Cited by 171
Cited by
Femtosecond stimulated Raman microscopy
Ploetz, E., Laimgruber, S., Berner, S., Zinth, W., & Gilch, P. (2007) · Applied Physics B · doi:10.1007/s00340-007-2630-x · Cited by 324
Combined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
Duke, A. R., Peterson, E., Mackanos, M. A., Atkinson, J., Tyler, D., & Jansen, E. D. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066006 · Cited by 45
Metadata
- Authors
- Khosrofian, J. M., & Garetz, B. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1983-11-01
- Volume
- 22
- Issue
- 21
- Pages
- 3406
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2096364868
- Cited by
- 368
- References
- 1
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.