Generation-V dual-Purkinje-image eyetracker
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Major advances characterize the Generation-V dual-Purkinje-image (DPI) eyetracker compared with the Generation-III version previously described. These advances include a large reduction in size, major improvements in frequency response and noise level, automatic alignment to a subject, and automatic adjustment for different separation between the visual and optic axes, which can vary considerably from subject to subject. In a number of applications described in the paper, the eyetracker is coupled with other highly specialized optical devices. These applications include accurately stabilizing an image on a subject's retina; accurately simulating a visually dead retinal region (i.e., a scotoma) of arbitrary shape, size, and position; and, for clinical purposes, stabilizing the position of a laser coagulator beam on a patient's retina so that the point of contact is unaffected by the patient's own eye movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accurate two-dimensional eye tracker using first and fourth Purkinje images
Cornsweet, T. N., & Crane, H. D. (1973) · Journal of the Optical Society of America · doi:10.1364/josa.63.000921 · Cited by 319
Self-citationOn Seeing Reddish Green and Yellowish Blue
Crane, H. D., & Piantanida, T. P. (1983) · Science · doi:10.1126/science.221.4615.1078 · Cited by 216
Self-citationRemote Measurement of Eye Direction Allowing Subject Motion Over One Cubic Foot of Space
Merchant, J., Morrissette, R., & Porterfield, J. L. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324318 · Cited by 174
Accurate three-dimensional eyetracker
Crane, H. D., & Steele, C. M. (1978) · Applied Optics · doi:10.1364/ao.17.000691 · Cited by 155
Self-citationThree-dimensional visual stimulus deflector
Crane, H. D., & Clark, M. R. (1978) · Applied Optics · doi:10.1364/ao.17.000706 · Cited by 75
Self-citationMotion and vision IV Isotropic and anisotropic spatial responses
Kelly, D. H. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000432 · Cited by 38
Cited by
Saccade target selection and object recognition: Evidence for a common attentional mechanism
Deubel, H., & Schneider, W. X. (1996) · Vision Research · doi:10.1016/0042-6989(95)00294-4 · Cited by 1,979
The effects of semantic consistency on eye movements during complex scene viewing.
Henderson, J. M., Weeks, P. A., Jr., & Hollingworth, A. (1999) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037//0096-1523.25.1.210 · Cited by 713
Accurate visual memory for previously attended objects in natural scenes.
Hollingworth, A., & Henderson, J. M. (2002) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/0096-1523.28.1.113 · Cited by 607
Effect of Remote Distractors on Saccade Programming: Evidence for an Extended Fixation Zone
Walker, R., Deubel, H., Schneider, W. X., & Findlay, J. M. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.78.2.1108 · Cited by 366
Eye Tracking in Advanced Interface Design
Jacob, R. J. K. (1995) · Virtual Environments and Advanced Interface Design · doi:10.1093/oso/9780195075557.003.0015 · Cited by 354
Metadata
- Authors
- Crane, H. D., & Steele, C. M.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1985-02-15
- Volume
- 24
- Issue
- 4
- Pages
- 527
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2100675880
- Cited by
- 291
- References
- 6
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.