Age and illuminance effects in the Farnsworth-Munsell 100-hue test
The DOI matches its Crossref record.
Abstract
Seventy-five normal volunteers (20-78 yr) were tested on the Farnsworth-Munsell 100-hue test at each of five illuminance levels. Each cap score distribution was analyzed by fitting a two-cycle sine wave whose amplitude and phase characterize the polarity of the error distribution and its axis. Analysis of these parameters reveals a similarity between tritanlike defects in older groups and those of younger groups at lower illuminance levels. These data are also useful for specifying age norms for the polarity of the error distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The retina in Parkinson's disease
Archibald, N. K., Clarke, M. P., Mosimann, U. P., & Burn, D. J. (2009) · Brain · doi:10.1093/brain/awp068 · Cited by 408
Mechanisms of photoreceptor death and survival in mammalian retina
Stone, J. (1999) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00032-9 · Cited by 291
Color rendering: A tale of two metrics
Rea, M. S., & Freyssinier‐Nova, J. P. (2008) · Color Research & Application · doi:10.1002/col.20399 · Cited by 228
“The literature consistently shows that illuminance levels of 100 fc or more are needed for the best performance on the Farnsworth–Munsell 100 hue test.(20,22,24) This study showed that color discrimination was always better at 50 fc than at 5 fc.”
BackgroundVisual dysfunction, neurodegenerative diseases, and aging
Jackson, G. R., & Owsley, C. (2003) · Neurologic Clinics · doi:10.1016/s0733-8619(02)00107-x · Cited by 226
Variation of chromatic sensitivity across the life span
Knoblauch, K., Vital-Durand, F., & Barbur, J. L. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00205-4 · Cited by 204
“…the Farnsworth-Munsell 100-hue test show decreasing errors with age until between 20 and 30 years of age (Verriest, 1963; Verriest, Laethem, & Uvijls, 1982) and thereafter error scores increase sys- tematically due to aging rather than developmental factors (Verriest, 1963; Knoblauch et al., 1987).”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Knoblauch, K., Saunders, F., Kusuda, M., Hynes, R., Podgor, M., Higgins, K. E., & de Monasterio, F. M.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1987-04-15
- Volume
- 26
- Issue
- 8
- Pages
- 1441
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2099270942
- Cited by
- 157
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Age and illuminance effects in the Farnsworth-Munsell 100-hue test. https://app.cochat.ai/papers/10.1364/ao.26.001441
- The paper
- Knoblauch, K., Saunders, F., Kusuda, M., Hynes, R., Podgor, M., Higgins, K. E., & de Monasterio, F. M. (1987). Age and illuminance effects in the Farnsworth-Munsell 100-hue test. Applied Optics. https://doi.org/10.1364/ao.26.001441
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.