Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record.

Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta

Keijzer, Marleen, Richards-Kortum, Rebecca R., Jacques, Steven L., Feld, Michael S.·1989·Applied Optics

Abstract

Fluorescence spectra of turbid media depend on the geometry of excitation and collection. The geometry dependence of 476-nm excited fluorescence of the human arterial wall was investigated both experimentally and with a Monte Carlo simulation. Optical properties and the fluorescence yield of each of the three arterial layers were determined. Attenuation of fluorescence by wavelength dependent scattering and reabsorption causes the fluorescence spectra observed at the tissue surface to change with distance from the excitation beam. The ratio of 600-nm fluorescence to 580-nm fluorescence increases significantly beyond the excitation beam. This ratio depends on the amount of oxyhemoglobin in the sample, illustrating how reabsorption can influence autofluorescence measurements. The effects of different excitation/collection geometries on fluorescence spectra are discussed in relation to the design of catheters to differentiate normal and pathologic tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.28.004286

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 222

Metadata

Authors
Keijzer, M., Richards-Kortum, R. R., Jacques, S. L., & Feld, M. S.
Venue
Applied Optics
Published
1989-10-15
Volume
28
Issue
20
Pages
4286
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2020663433
Cited by
222
References
0
FWCI
5.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta. https://app.cochat.ai/papers/10.1364/ao.28.004286
The paper
Keijzer, M., Richards-Kortum, R. R., Jacques, S. L., & Feld, M. S. (1989). Fluorescence spectroscopy of turbid media: Autofluorescence of the human aorta. Applied Optics. https://doi.org/10.1364/ao.28.004286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.