The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Quantitative determination of the absorption spectra of chromophores in strongly scattering media: a light-emitting-diode based technique
Open accessAbstract
The absorption and scattering coefficient of a macroscopically homogeneous strongly scattering medium (lipid emulsion) containing Methylene Blue is quantitatively measured in the spectral range from 620 to 700 nm. We conduct the measurements in the frequency domain by using a light-emitting diode (LED) whose intensity is modulated at a frequency of 60 MHz. We derive an analytical expression for the absorption and scattering coefficients that is based on a two-distance measurement technique. A comparison with other measurement protocols such as measurement at two modulation frequencies shows that the two-distance method gives a better determination of the scattering and absorption coefficients. This study highlights the efficiency and ease of use of the LED technique, which lends itself to in vivo spectroscopy of biological tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Properties of ordinary water-substance
Oppermann, R. H. (1940) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(40)90750-5 · Cited by 830
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Self-citationThe physics of photodynamic therapy
Wilson, B. C., & Patterson, M. S. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/4/001 · Cited by 338
(1982) · Springer eBooks · doi:10.1007/978-1-4684-8312-3 · Cited by 301
Reflectance spectrophotometry of cytochrome aa3 in vivo
Jobsis, F. F., Keizer, J. H., LaManna, J. C., & Rosenthal, M. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.5.858 · Cited by 282
Cited by
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Self-citationMourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Contini, D., Martelli, F., & Zaccanti, G. (1997) · Applied Optics · doi:10.1364/ao.36.004587 · Cited by 460
Metadata
- Authors
- Fantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1994-08-01
- Volume
- 33
- Issue
- 22
- Pages
- 5204
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2014885692
- Cited by
- 259
- References
- 17
- FWCI
- 16.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative determination of the absorption spectra of chromophores in strongly scattering media: a light-emitting-diode based technique. https://app.cochat.ai/papers/10.1364/ao.33.005204
- The paper
- Fantini, S., Franceschini, M. A., Fishkin, J. B., Barbieri, B., & Gratton, E. (1994). Quantitative determination of the absorption spectra of chromophores in strongly scattering media: a light-emitting-diode based technique. Applied Optics. https://doi.org/10.1364/ao.33.005204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.