Single-photon detection beyond 1 μm: performance of commercially available germanium photodiodes
The DOI matches its Crossref record.
Abstract
Germanium avalanche photodiodes (APD's) working biased above the breakdown voltage detect single optical photons in the near-infrared wavelength range. We give guidelines for the selection of devices suitable for photon-counting applications among the commercial samples, and we discuss in detail how the devices should be operated to achieve the best performance, both in terms of noise-equivalent power (NEP) and the timing-equivalent bandwidth. We introduce the driving electronics and we show that, in the measurements of fast optical signals, the adoption of single-photon techniques is very favorable, notwithstanding that presently available photodiodes are not designed for this purpose. On the contrary, in the detection of cw signals, the lower NEP values achieved in photon counting may not be sufficient to justify the replacement of conventional analog p-i-n germanium detectors, which offer comparable performance with a definitely larger sensitive area. Finally, we show that, by properly choosing theoperating conditions, some selected APD's achieve an 85-ps time resolution in the detection of optical photons at a 1.3-µm wavelength, which corresponds to a timing-equivalent bandwidth of 1.8 GHz. To the best of our knowledge, this time resolution is the lowest reported to date for single-photon detectors in the near infrared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Avalanche photodiodes and quenching circuits for single-photon detection
Cova, S., Ghioni, M., Lacaita, A., Samori, C., & Zappa, F. (1996) · Applied Optics · doi:10.1364/ao.35.001956 · Cited by 1,114
Self-citationEvolution and prospects for single-photon avalanche diodes and quenching circuits
Cova, S., Ghioni, M., Lotito, A., Rech, I., & Zappa, F. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235272 · Cited by 322
Self-citationAdvances in cost-effective integrated spectrometers
Li, A., Yao, C., Xia, J., Wang, H., Cheng, Q., Penty, R., Fainman, Y., & Pan, S. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00853-1 · Cited by 309
Single-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
Performance of InGaAs/InP avalanche photodiodes as gated-mode photon counters
Ribordy, G., Gautier, J.-D., Zbinden, H., & Gisin, N. (1998) · Applied Optics · doi:10.1364/ao.37.002272 · Cited by 194
Single-photon detection beyond 1 μm: performance of commercially available InGaAs/InP detectors
Lacaita, A., Zappa, F., Cova, S., & Lovati, P. (1996) · Applied Optics · doi:10.1364/ao.35.002986 · Cited by 167
Self-citationPhoton counting for quantum key distribution with peltier cooled InGaAs/InP APDs
Stucki, D., Ribordy, G., Stefanov, A., Zbinden, H., Rarity, J. G., & Wall, T. (2001) · Journal of Modern Optics · doi:10.1080/09500340108240900 · Cited by 159
Performance and design of InGaAs/InP photodiodes for single-photon counting at 155 µm
Hiskett, P. A., Buller, G. S., Loudon, A. Y., Smith, J. M., Gontijo, I., Walker, A. C., Townsend, P. D., & Robertson, M. J. (2000) · Applied Optics · doi:10.1364/ao.39.006818 · Cited by 126
“3y2 yq\EI!, ( 1 ) where u5a ~m*ym0! 1y2 . a depends on the details of the tunneling barrier, and it is usually assumed that a > 1 and”
Background
Metadata
- Authors
- Lacaita, A., Francese, P. A., Zappa, F., & Cova, S.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1994-10-20
- Volume
- 33
- Issue
- 30
- Pages
- 6902
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2036906963
- Cited by
- 87
- References
- 0
- FWCI
- 19.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.