The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Mie and Rayleigh modeling of visible-light scattering in neonatal skin
Abstract
Reduced-scattering coefficients of neonatal skin were deduced in the 450-750-nm range from integrating-sphere measurements of the total reflection and total transmission of 22 skin samples. The reduced-scattering coefficients increased linearly at each wavelength with gestational maturity. The distribution of diameters d and concentration ρ(A) of the skin-sample collagen fibers were measured in histological sections of nine neonatal skin samples of varying gestational ages. An algorithm that calculates Mie scattering by cylinders was used to model the scattering by the collagen fibers in the skin. The fraction of the reduced-scattering coefficient µ(s)' that was attributable to Mie scattering by collagen fibers, as deduced from wavelength-dependent analysis, increased with gestational age and approached that found for adult skin. An assignment of 1.017 for n(rel), the refractive index of the collagen fibers relative to that of the surrounding medium, allowed the values for Mie scattering by collagen fibers, as predicted by the model for each of the nine neonatal skin samples to match the values for Mie scattering by collagen fibers as expected from the measurements of µ(s)'. The Mie-scattering model predicted an increase in scattering with gestational age on the basis of changes in the collagen-fiber diameters, and this increase was proportional to that measured with the integrating-sphere method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Collagen types I, III, and V in human embryonic and fetal skin
Smith, L. T., Holbrook, K. A., & Madri, J. A. (1986) · American Journal of Anatomy · doi:10.1002/aja.1001750409 · Cited by 207
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Bigio, I. J., & Mourant, J. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/005 · Cited by 373
Metadata
- Authors
- Saidi, I. S., Jacques, S. L., & Tittel, F. K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1995-11-01
- Volume
- 34
- Issue
- 31
- Pages
- 7410
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2056431986
- Cited by
- 294
- References
- 2
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mie and Rayleigh modeling of visible-light scattering in neonatal skin. https://app.cochat.ai/papers/10.1364/ao.34.007410
- The paper
- Saidi, I. S., Jacques, S. L., & Tittel, F. K. (1995). Mie and Rayleigh modeling of visible-light scattering in neonatal skin. Applied Optics. https://doi.org/10.1364/ao.34.007410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.