Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 294

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Mie and Rayleigh modeling of visible-light scattering in neonatal skin

Saidi, Iyad S., Jacques, Steven L., Tittel, Frank K.·1995·Applied Optics

Abstract

Reduced-scattering coefficients of neonatal skin were deduced in the 450-750-nm range from integrating-sphere measurements of the total reflection and total transmission of 22 skin samples. The reduced-scattering coefficients increased linearly at each wavelength with gestational maturity. The distribution of diameters d and concentration ρ(A) of the skin-sample collagen fibers were measured in histological sections of nine neonatal skin samples of varying gestational ages. An algorithm that calculates Mie scattering by cylinders was used to model the scattering by the collagen fibers in the skin. The fraction of the reduced-scattering coefficient µ(s)' that was attributable to Mie scattering by collagen fibers, as deduced from wavelength-dependent analysis, increased with gestational age and approached that found for adult skin. An assignment of 1.017 for n(rel), the refractive index of the collagen fibers relative to that of the surrounding medium, allowed the values for Mie scattering by collagen fibers, as predicted by the model for each of the nine neonatal skin samples to match the values for Mie scattering by collagen fibers as expected from the measurements of µ(s)'. The Mie-scattering model predicted an increase in scattering with gestational age on the basis of changes in the collagen-fiber diameters, and this increase was proportional to that measured with the integrating-sphere method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.34.007410

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 294

Metadata

Authors
Saidi, I. S., Jacques, S. L., & Tittel, F. K.
Venue
Applied Optics
Published
1995-11-01
Volume
34
Issue
31
Pages
7410
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2056431986
Cited by
294
References
2
FWCI
2.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mie and Rayleigh modeling of visible-light scattering in neonatal skin. https://app.cochat.ai/papers/10.1364/ao.34.007410
The paper
Saidi, I. S., Jacques, S. L., & Tittel, F. K. (1995). Mie and Rayleigh modeling of visible-light scattering in neonatal skin. Applied Optics. https://doi.org/10.1364/ao.34.007410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.