The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Mie and Rayleigh modeling of visible-light scattering in neonatal skin
Abstract
Reduced-scattering coefficients of neonatal skin were deduced in the 450-750-nm range from integrating-sphere measurements of the total reflection and total transmission of 22 skin samples. The reduced-scattering coefficients increased linearly at each wavelength with gestational maturity. The distribution of diameters d and concentration ρ(A) of the skin-sample collagen fibers were measured in histological sections of nine neonatal skin samples of varying gestational ages. An algorithm that calculates Mie scattering by cylinders was used to model the scattering by the collagen fibers in the skin. The fraction of the reduced-scattering coefficient µ(s)' that was attributable to Mie scattering by collagen fibers, as deduced from wavelength-dependent analysis, increased with gestational age and approached that found for adult skin. An assignment of 1.017 for n(rel), the refractive index of the collagen fibers relative to that of the surrounding medium, allowed the values for Mie scattering by collagen fibers, as predicted by the model for each of the nine neonatal skin samples to match the values for Mie scattering by collagen fibers as expected from the measurements of µ(s)'. The Mie-scattering model predicted an increase in scattering with gestational age on the basis of changes in the collagen-fiber diameters, and this increase was proportional to that measured with the integrating-sphere method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Self-citationRefractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Noninvasive detection of changes in membrane potential in cultured neurons by light scattering.
Stepnoski, R. A., LaPorta, A., Raccuia-Behling, F., Blonder, G. E., Slusher, R. E., & Kleinfeld, D. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.21.9382 · Cited by 255
Optical Properties of Human Skin
Anderson, R. R., & Parrish, J. A. (1982) · The Science of Photomedicine · doi:10.1007/978-1-4684-8312-3_6 · Cited by 250
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Graaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
“Scatter from filamentous proteins has been approximated using a Mie solution to Maxwell’s equations applied to data from in vitro skin samples.(47,48) This approach provides an increase in simulated scattering probability with increasing fiber diameter and decreasing wavelength.”
MethodCorrigendum: Optical properties of biological tissues: a review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/14/5007 · Cited by 430
Self-citationBigio, I. J., & Mourant, J. R. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/005 · Cited by 373
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Three-dimensional computation of light scattering from cells
Dunn, A., & Richards-Kortum, R. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577313 · Cited by 275
Kaufman, L. J., Brangwynne, C. P., Kasza, K. E., Filippidi, E., Gordon, V. D., Deisboeck, T. S., & Weitz, D. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061994 · Cited by 259
Origins of Tissue Optical Properties in the UVA, Visible, and NIR Regions
Jacques, S. L. (1996) · Advances in Optical Imaging and Photon Migration · doi:10.1364/aoipm.1996.opc364 · Cited by 247
Self-citationNachabe, R., Hendriks, B. H., Lucassen, G. W., van der Voort, M., Evers, D. J., Rutgers, E. J., Peeters, M.-J. V., Van der Hage, J. A., Oldenburg, H. S., Ruers, T. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3611010 · Cited by 161
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52
Optical properties of neonatal skin measured in vivo as a function of age and skin pigmentation
Bosschaart, N., Mentink, R., van Leeuwen, A. G. J. M. T., Aalders, M. C., & Kok, J. H. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3622629 · Cited by 49
Mignon, C., Tobin, D. J., Zeitouny, M., & Uzunbajakava, N. E. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.000852 · Cited by 43
Metadata
- Authors
- Saidi, I. S., Jacques, S. L., & Tittel, F. K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1995-11-01
- Volume
- 34
- Issue
- 31
- Pages
- 7410
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2056431986
- Cited by
- 294
- References
- 15
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.