Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record.

Two-modulator generalized ellipsometry: experiment and calibration

Jellison, G. E., Modine, F. A.·1997·Applied Optics

Abstract

A two-modulator generalized ellipsometer is described that is capable of measuring all 16 elements of a sample Mueller matrix with four measurements made at different azimuthal orientations of the polarization state generator and polarization state detector. If the sample can be described with a Mueller-Jones matrix, only a single measurement is needed. Only two calibration steps are needed to determine the fundamental operating parameters of the instrument. A reflection measurement from silicon is presented as an example, which illustrates that the elements of the Mueller-Jones matrix can be measured to an accuracy of ~0.1-0.2%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.36.008184

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Jellison, G. E., & Modine, F. A.
Venue
Applied Optics
Published
1997-11-01
Volume
36
Issue
31
Pages
8184
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2110667992
Cited by
178
References
0
FWCI
6.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two-modulator generalized ellipsometry: experiment and calibration. https://app.cochat.ai/papers/10.1364/ao.36.008184
The paper
Jellison, G. E., & Modine, F. A. (1997). Two-modulator generalized ellipsometry: experiment and calibration. Applied Optics. https://doi.org/10.1364/ao.36.008184

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.