Two-modulator generalized ellipsometry: experiment and calibration
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A two-modulator generalized ellipsometer is described that is capable of measuring all 16 elements of a sample Mueller matrix with four measurements made at different azimuthal orientations of the polarization state generator and polarization state detector. If the sample can be described with a Mueller-Jones matrix, only a single measurement is needed. Only two calibration steps are needed to determine the fundamental operating parameters of the instrument. A reflection measurement from silicon is presented as an example, which illustrates that the elements of the Mueller-Jones matrix can be measured to an accuracy of ~0.1-0.2%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical functions of silicon determined by two-channel polarization modulation ellipsometry
Jellison, G. E. (1992) · Optical Materials · doi:10.1016/0925-3467(92)90015-f · Cited by 338
Self-citationTwo-channel polarization modulation ellipsometer
Jellison, G. E., & Modine, F. A. (1990) · Applied Optics · doi:10.1364/ao.29.000959 · Cited by 86
Self-citation
Cited by
Spectroscopic ellipsometry data analysis: measured versus calculated quantities
Jellison, Jr. (1998) · Thin Solid Films · doi:10.1016/s0040-6090(97)00765-7 · Cited by 372
Wide bandgap tunability in complex transition metal oxides by site-specific substitution
Choi, W. S., Chisholm, M. F., Singh, D. J., Choi, T., Jellison, G. E., & Lee, H. N. (2012) · Nature Communications · doi:10.1038/ncomms1690 · Cited by 291
Self-citation(2013) · Springer eBooks · doi:10.1007/978-3-642-33956-1 · Cited by 267
Spectroscopic ellipsometry of thin film and bulk anatase (TiO2)
Jellison, G. E., Boatner, L. A., Budai, J. D., Jeong, B.-S., & Norton, D. P. (2003) · Journal of Applied Physics · doi:10.1063/1.1573737 · Cited by 258
Self-citationOptimization of a dual-rotating-retarder Mueller matrix polarimeter
Smith, M. H. (2002) · Applied Optics · doi:10.1364/ao.41.002488 · Cited by 198
Buhse, T., Cruz, J.-M., Noble-Terán, M. E., Hochberg, D., Ribó, J. M., Crusats, J., & Micheau, J.-C. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00819 · Cited by 189
Quantitative measurement of birefringence in transparent films across the visible spectrum
Slepkov, A. D. (2022) · American Journal of Physics · doi:10.1119/5.0087798 · Cited by 1
Metadata
- Authors
- Jellison, G. E., & Modine, F. A.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1997-11-01
- Volume
- 36
- Issue
- 31
- Pages
- 8184
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2110667992
- Cited by
- 178
- References
- 2
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.