The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Optimization of a dual-rotating-retarder Mueller matrix polarimeter
Abstract
The dual-rotating-retarder configuration is one of the most common forms of the Mueller matrix polarimeter. I perform an optimization of this polarimeter configuration by minimizing the condition number of the system data reduction matrix. I find the optimum retardance for the rotating retarders to be 127 degrees. If exactly 16 intensity measurements are used for a Mueller matrix calculation, a complex relationship exists between the condition number and the sizes of the angular increments of the two retarders. If many intensity measurements are made, thus overspecifying the calculation, I find broad optimal ranges of angular increments of the two retarders that yield essentially equal performance. Experimental results are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409
Cited by
Review of passive imaging polarimetry for remote sensing applications
Tyo, J. S., Goldstein, D. L., Chenault, D. B., & Shaw, J. A. (2006) · Applied Optics · doi:10.1364/ao.45.005453 · Cited by 1,716
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Stokes-vector and Mueller-matrix polarimetry [Invited]
Azzam, R. M. A. (2016) · Journal of the Optical Society of America A · doi:10.1364/josaa.33.001396 · Cited by 259
Optimal Frames for Polarization State Reconstruction
Foreman, M. R., Favaro, A., & Aiello, A. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.263901 · Cited by 90
Metadata
- Authors
- Smith, M. H.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2002-05-01
- Volume
- 41
- Issue
- 13
- Pages
- 2488
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2020686016
- Cited by
- 198
- References
- 1
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of a dual-rotating-retarder Mueller matrix polarimeter. https://app.cochat.ai/papers/10.1364/ao.41.002488
- The paper
- Smith, M. H. (2002). Optimization of a dual-rotating-retarder Mueller matrix polarimeter. Applied Optics. https://doi.org/10.1364/ao.41.002488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.