The DOI matches its Crossref record.
Changes in spectral shape of tissue optical properties in conjunction with laser-induced thermotherapy
Open accessAbstract
We measured the optical properties on samples of rat liver tissue before and after laser-induced thermotherapy performed in vivo with Nd:YAG laser irradiation. This made it possible to monitor not only the influence of coagulation on the scattering properties but also the influence of damages to vessels and heat-induced damage to blood on the absorption properties. An experimental integrating-sphere arrangement was modified to allow the determination of the g factor and the absorption and scattering coefficients versus the wavelength in the 600-1050-nm spectral region, with the use of a spectrometer and a CCD camera. The results show a relative decrease in the g factor of on average 21 ? 7% over the entire spectral range following thermotherapy, and a corresponding relative increase in the scattering and absorption coefficients of 23 ? 8% and 200 ? 100%, respectively. An increase of on average 200 ? 80% was consequently found for the reduced scattering coefficient. The cause of these changes in terms of the Mie-equivalent average radius of tissue scatterers as well as of the distribution and biochemistry of tissue absorbers was analyzed, utilizing the information yielded by the g factor and the spectral shapes of the reduced scattering and absorption coefficients. These results were correlated with the alterations in the ultrastructure found in the histological evaluation. The average radius of tissue scattering centers, determined by using either the g factors calculated on the basis of Mie theory or the spectral shape of reduced scattering coefficients calculated on the Mie theory, was estimated to be 21-32% lower in treated than in untreated liver samples. The Mie-equivalent average radii of scattering centers in untreated liver tissue deduced by the two methods corresponded well and were found to be 0.31 and 0.29 mum, respectively, yielding particle sizes in the same range as the size of a mitochondrion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Bulk optical properties of healthy female breast tissue
Durduran, T., Choe, R., Culver, J. P., Zubkov, L., Holboke, M. J., Giammarco, J., Chance, B., & Yodh, A. G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/302 · Cited by 291
Metadata
- Authors
- Nilsson, A. M. K., Sturesson, C., Liu, D. L., & Andersson-Engels, S.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1998-03-01
- Volume
- 37
- Issue
- 7
- Pages
- 1256
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2039181023
- Cited by
- 190
- References
- 0
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Changes in spectral shape of tissue optical properties in conjunction with laser-induced thermotherapy. https://app.cochat.ai/papers/10.1364/ao.37.001256
- The paper
- Nilsson, A. M. K., Sturesson, C., Liu, D. L., & Andersson-Engels, S. (1998). Changes in spectral shape of tissue optical properties in conjunction with laser-induced thermotherapy. Applied Optics. https://doi.org/10.1364/ao.37.001256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.