Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 369

The DOI matches its Crossref record.

General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers

Compain, Eric, Poirier, Stéphane, Drevillon, Bernard·1999·Applied Optics

Abstract

Calibration of polarization-state generators (PSG's), polarimeters, and Mueller-matrix ellipsometers (MME's) is an important factor in the practical use of these instruments. A new general procedure, the eigenvalue calibration method (ECM), is presented. It can calibrate any complete MME consisting of a PSG and a polarimeter that generate and measure, respectively, all the states of polarization of light. In the ECM, the PSG and the polarimeter are described by two 4 x 4 matrices W and A, and their 32 coefficients are determined from three or four measurements performed on reference samples. Those references are smooth isotropic samples and perfect linear polarizers. Their optical characteristics are unambiguously determined during the calibration from the eigenvalues of the measured matrices. The ECM does not require accurate alignment of the various optical elements and does not involve any first-order approximation. The ECM also displays an efficient error control capability that can be used to improve the MME behavior. The ECM is illustrated by an experimental calibration, at two wavelengths (458 and 633 nm), of a MME consisting of a coupled phase modulator associated with a prism division-of-amplitude polarimeter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.38.003490

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 369

Metadata

Authors
Compain, E., Poirier, S., & Drevillon, B.
Venue
Applied Optics
Published
1999-06-01
Volume
38
Issue
16
Pages
3490
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2031236990
Cited by
369
References
0
FWCI
1.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers. https://app.cochat.ai/papers/10.1364/ao.38.003490
The paper
Compain, E., Poirier, S., & Drevillon, B. (1999). General and self-consistent method for the calibration of polarization modulators, polarimeters, and Mueller-matrix ellipsometers. Applied Optics. https://doi.org/10.1364/ao.38.003490

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.