The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Light scattering from cells: finite-difference time-domain simulations and goniometric measurements
Abstract
We have examined the light-scattering properties of inhomogeneous biological cells through a combination of theoretical simulations and goniometric measurements. A finite-difference time-domain (FDTD) technique was used to compute intensity as a function of scattering angle for cells containing multiple organelles and spatially varying index of refraction profiles. An automated goniometer was constructed to measure the scattering properties of dilute cell suspensions. Measurements compared favorably with FDTD predictions. FDTD and experimental results indicate that scattering properties are strongly influenced by cellular biochemical and morphological structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M., Grossman, M., Esterowitz, D., Webb, R. H., & Rox Anderson, R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,093
Hartmann, M. (1984) · Acta Polymerica · doi:10.1002/actp.1984.010350426 · Cited by 1,071
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Perelman, L. T., Backman, V., Wallace, M., Zonios, G., Manoharan, R., Nusrat, A., Shields, S., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 491
Optical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Three-dimensional computation of light scattering from cells
Dunn, A., & Richards-Kortum, R. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577313 · Cited by 275
Self-citationFishkin, J. B., Coquoz, O., Anderson, E. R., Brenner, M., & Tromberg, B. J. (1997) · Applied Optics · doi:10.1364/ao.36.000010 · Cited by 259
Spectroscopic diagnosis of bladder cancer with elastic light scattering
Mourant, J. R., Bigio, I. J., Boyer, J., Conn, R. L., Johnson, T., & Shimada, T. (1995) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900170403 · Cited by 250
T-matrix computations of light scattering by red blood cells
Nilsson, A. M. K., Alsholm, P., Karlsson, A., & Andersson‐Engels, S. (1998) · Applied Optics · doi:10.1364/ao.37.002735 · Cited by 129
Valkenburg, J. A. C., & Woldringh, C. L. (1984) · Journal of Bacteriology · doi:10.1128/jb.160.3.1151-1157.1984 · Cited by 110
OPTICAL AND THERMAL CHARACTERIZATION OF NATURAL (Sepia officinalis) MELANIN
Vitkin, I. A., Woolsey, J., Wilson, B. C., & Anderson, R. R. (1994) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1994.tb05064.x · Cited by 97
Light scattering multipole solution for a cell
Videen, G. W., & Ngo, D. D. (1998) · Journal of Biomedical Optics · doi:10.1117/1.429877 · Cited by 35
Cited by
Nuclear Architecture of Rod Photoreceptor Cells Adapts to Vision in Mammalian Evolution
Solovei, I., Kreysing, M., Lanctôt, C., Kösem, S., Peichl, L., Cremer, T., Guck, J., & Joffe, B. (2009) · Cell · doi:10.1016/j.cell.2009.01.052 · Cited by 790
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Light scattering from cells: the contribution of the nucleus and the effects of proliferative status
Mourant, J. R., Canpolat, M., Brocker, C., Esponda-Ramos, O., Johnson, T. M., Matanock, A., Stetter, K., & Freyer, J. P. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429979 · Cited by 261
Drezek, R., Guillaud, M., Collier, T., Boiko, I., Malpica, A., Macaulay, C., Follen, M., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528950 · Cited by 255
Self-citationCan spherical eukaryotic microalgae cells be treated as optically homogeneous?
Bhowmik, A., & Pilon, L. (2016) · Journal of the Optical Society of America A · doi:10.1364/josaa.33.001495 · Cited by 30
Metadata
- Authors
- Drezek, R., Dunn, A., & Richards-Kortum, R.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1999-06-01
- Volume
- 38
- Issue
- 16
- Pages
- 3651
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2109868570
- Cited by
- 312
- References
- 14
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.