Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 537

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser

Minoshima, Kaoru, Matsumoto, Hirokazu·2000·Applied Optics

Abstract

A high-accuracy optical distance meter with a mode-locked femtosecond laser is proposed for distance measurements in a 310-m-long optical tunnel. We measured the phase shift of the optical beat component between longitudinal modes of a mode-locked laser. A high resolution of 50 microm at 240-m distance was obtained without cyclic error correction. The group refractive index of air is automatically extracted to an accuracy of 6 parts per million (ppm) by two-color measurement with the pulses of fundamental and second-harmonic wavelengths. Finally, an absolute mechanical distance of 240 m was obtained to within 8-ppm accuracy by use of a series of beat frequencies with the advantage of a wide range of intermode frequency, together with the results of the two-color measurement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ao.39.005512

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 537

Metadata

Authors
Minoshima, K., & Matsumoto, H.
Venue
Applied Optics
Published
2000-10-20
Volume
39
Issue
30
Pages
5512
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2115744554
Cited by
537
References
2
FWCI
1.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser. https://app.cochat.ai/papers/10.1364/ao.39.005512
The paper
Minoshima, K., & Matsumoto, H. (2000). High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser. Applied Optics. https://doi.org/10.1364/ao.39.005512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.