Fluorescence from airborne microparticles: dependence on size, concentration of fluorophores, and illumination intensity
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We measured fluorescence from spherical water droplets containing tryptophan and from aggregates of bacterial cells and compared these measurements with calculations of fluorescence of dielectric spheres. The measured dependence of fluorescence on size, from both droplets and dry-particle aggregates of bacteria, is proportional to the absorption cross section calculated for homogeneous spheres containing the appropriate percentage of tryptophan. However, as the tryptophan concentration of the water droplets is increased, the measured fluorescence from droplets increases less than predicted, probably because of concentration quenching. We model the dependence of the fluorescence on input intensity by assuming that the average time between fluorescence emission events is the sum of the fluorescence lifetime and the excitation lifetime (the average time it takes for an illuminated molecule to be excited), which we calculated assuming that the intensity inside the particle is uniform. Even though the intensity inside the particles spatially varies, this assumption of uniform intensity still leads to results consistent with the measured intensity dependence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hairston, P. P., Ho, J., & Quant, F. R. (1997) · Journal of Aerosol Science · doi:10.1016/s0021-8502(96)00448-x · Cited by 231
Pan, Y.-L., Holler, S., Chang, R. K., Hill, S. C., Pinnick, R. G., Niles, S., & Bottiger, J. R. (1999) · Optics Letters · doi:10.1364/ol.24.000116 · Cited by 111
Self-citation
Cited by
Real-time sensing of bioaerosols: Review and current perspectives
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon, F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., et al. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1664724 · Cited by 299
Self-citationGabey, A. M., Gallagher, M. W., Whitehead, J., Dorsey, J. R., Kaye, P. H., & Stanley, W. R. (2010) · Atmospheric Chemistry and Physics · doi:10.5194/acp-10-4453-2010 · Cited by 195
“The intensity of Tryptophan-like fluorescence from clusters of bacteria (Hill et al., 2001) increases in line with the cluster's absorption cross-section.”
BackgroundToprak, E., & Schnaiter, M. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-225-2013 · Cited by 171
Healy, D. A., Huffman, J. A., O'Connor, D. J., Pöhlker, C., Pöschl, U., & Sodeau, J. R. (2014) · Atmospheric Chemistry and Physics · doi:10.5194/acp-14-8055-2014 · Cited by 101
The fluorescence properties of aerosol larger than 0.8 μm in urban and tropical rainforest locations
Gabey, A. M., Stanley, W. R., Gallagher, M. W., & Kaye, P. H. (2011) · Atmospheric Chemistry and Physics · doi:10.5194/acp-11-5491-2011 · Cited by 97
Metadata
- Authors
- Hill, S. C., Pinnick, R. G., Niles, S., Fell, N. F., Pan, Y.-L., Bottiger, J., Bronk, B. V., Holler, S., & Chang, R. K.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2001-06-20
- Volume
- 40
- Issue
- 18
- Pages
- 3005
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2068393525
- Cited by
- 71
- References
- 2
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence from airborne microparticles: dependence on size, concentration of fluorophores, and illumination intensity. https://app.cochat.ai/papers/10.1364/ao.40.003005
- The paper
- Hill, S. C., Pinnick, R. G., Niles, S., Fell, N. F., Pan, Y.-L., Bottiger, J., Bronk, B. V., Holler, S., & Chang, R. K. (2001). Fluorescence from airborne microparticles: dependence on size, concentration of fluorophores, and illumination intensity. Applied Optics. https://doi.org/10.1364/ao.40.003005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.