Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in a microarray format
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We describe a recently developed oblique-incidence reflectivity difference (OI-RD) microscope, a form of polarization-modulated imaging ellipsometer, for label-free-high-throughput detection of biomolecular reactions on DNA and protein microarrays. We present examples of application of this technique to end-point and real-time investigations of DNA-DNA hybridization, antibody-antigen capture, and protein-small-molecule binding reactions. Compared to a conventional imaging ellipsometer based on the polarizer-compensator-sample-analyzer scheme and under the off-null condition, a polarization-modulated OI-RD microscope is inherently more sensitive by at least 1 order of magnitude to thickness changes on a solid surface. Compared with imaging surface plasmon resonance microscopes based on reflectance change on falling or rising slopes of the surface plasmon resonance, the OI-RD microscope (1) has a comparable sensitivity, (2) is applicable to conventional microscope glass slides, and (3) easily covers a field of view as large as the entire surface of a 1 in. x 3 in. (2.54 cm x 7.62 cm) microscope slide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884
Jin, G., Jansson, R., & Arwin, H. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147074 · Cited by 195
Cited by
Allele-selective lowering of mutant HTT protein by HTT–LC3 linker compounds
Li, Z., Wang, C., Wang, Z., Zhu, C., Li, J., Sha, T., Ma, L., Gao, C., Yang, Y., Sun, Y., et al. (2019) · Nature · doi:10.1038/s41586-019-1722-1 · Cited by 551
Self-citationDNA methylation presents distinct binding sites for human transcription factors
Hu, S., Wan, J., Su, Y., Song, Q., Zeng, Y., Nguyen, H. N., Shin, J., Cox, E., Rho, H. S., Woodard, C., et al. (2013) · eLife · doi:10.7554/elife.00726 · Cited by 349
“KD measurement of transcription factors binding 5mCpG motifs Binding affinity between a transcriptional factor and a methylated DNA motif was determined by the oblique incidence reflection difference (OIRD) method (Landry et al., 2004; Zhu et al., 2007; Fei et al., 2011).”
MethodInfluentialTargeting Lysosomal Degradation Pathways: New Strategies and Techniques for Drug Discovery
Pei, J., Wang, G., Feng, L., Zhang, J., Jiang, T., Sun, Q., & Ouyang, L. (2021) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.0c01689 · Cited by 124
Metadata
- Authors
- Zhu, X., Landry, J. P., Sun, Y.-S., Gregg, J. P., Lam, K. S., & Guo, X.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2007-03-13
- Volume
- 46
- Issue
- 10
- Pages
- 1890
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2092857895
- Cited by
- 72
- References
- 2
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in a microarray format. https://app.cochat.ai/papers/10.1364/ao.46.001890
- The paper
- Zhu, X., Landry, J. P., Sun, Y.-S., Gregg, J. P., Lam, K. S., & Guo, X. (2007). Oblique-incidence reflectivity difference microscope for label-free high-throughput detection of biochemical reactions in a microarray format. Applied Optics. https://doi.org/10.1364/ao.46.001890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.