Cited by 15Terahertz technology and applicationsAdvanced optical system designAdvanced X-ray Imaging Techniques

Design and evaluation of a THz time domain imaging system using standard optical design software

Brückner, Claudia, Pradarutti, Boris, Müller, Ralf, Riehemann, Stefan, Notni, Gunther, Tünnermann, Andreas·2008·Applied Optics

Abstract

A terahertz (THz) time domain imaging system is analyzed and optimized with standard optical design software (ZEMAX). Special requirements to the illumination optics and imaging optics are presented. In the optimized system, off-axis parabolic mirrors and lenses are combined. The system has a numerical aperture of 0.4 and is diffraction limited for field points up to 4 mm and wavelengths down to 750 microm. ZEONEX is used as the lens material. Higher aspherical coefficients are used for correction of spherical aberration and reduction of lens thickness. The lenses were manufactured by ultraprecision machining. For optimization of the system, ray tracing and wave-optical methods were combined. We show how the ZEMAX Gaussian beam analysis tool can be used to evaluate illumination optics. The resolution of the THz system was tested with a wire and a slit target, line gratings of different period, and a Siemens star. The behavior of the temporal line spread function can be modeled with the polychromatic coherent line spread function feature in ZEMAX. The spectral and temporal resolutions of the line gratings are compared with the respective modulation transfer function of ZEMAX. For maximum resolution, the system has to be diffraction limited down to the smallest wavelength of the spectrum of the THz pulse. Then, the resolution on time domain analysis of the pulse maximum can be estimated with the spectral resolution of the center of gravity wavelength. The system resolution near the optical axis on time domain analysis of the pulse maximum is 1 line pair/mm with an intensity contrast of 0.22. The Siemens star is used for estimation of the resolution of the whole system. An eight channel electro-optic sampling system was used for detection. The resolution on time domain analysis of the pulse maximum of all eight channels could be determined with the Siemens star to be 0.7 line pairs/mm.

Integrity signals

Registry

Crossref · 10.1364/ao.47.004994

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Authors
Brückner, C., Pradarutti, B., Müller, R., Riehemann, S., Notni, G., & Tünnermann, A.
Affiliations
Fraunhofer Institute for Applied Optics and Precision Engineering (DE)
Venue
Applied Optics
Published
2008-09-18
Volume
47
Issue
27
Pages
4994
ISSN
  • 0003-6935 (ISSN-L)
  • 1539-4522
OpenAlex
W2036236745
Cited by
15
References
10
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2014: 3
FWCI
1.20
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Optics (publishedVersion)
  • PubMed (publishedVersion)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced optical system design
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
Keywords
terahertz time-domain imaging, optical design, off-axis parabolic mirror, Zemax, illumination optics, diffraction-limited resolution, line spread function, modulation transfer function, Siemens star, line gratings, spherical aberration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›