Cited by 499Terahertz technology and applicationsLaser-Matter Interactions and ApplicationsAdvanced Semiconductor Detectors and Materials

Terahertz time-domain spectroscopy characterization of the far-infrared absorption and index of refraction of high-resistivity, float-zone silicon

Dai, Jianming, Zhang, Jiangquan, Zhang, Weili, Grischkowsky, D.·2004·Journal of the Optical Society of America B

Abstract

The far-infrared absorption and index of refraction of high-resistivity, float-zone, crystalline silicon has been measured by terahertz time-domain spectroscopy. The measured new upper limit for the absorption of this most transparent dielectric material in the far infrared shows unprecedented transparency over the range from 0.5 to 2.5 THz and a well-resolved absorption feature at 3.6 THz. The index of refraction shows remarkably little dispersion, changing by only 0.0001 over the range from 0.5 to 4.5 THz.

Integrity signals

Registry

Crossref · 10.1364/josab.21.001379

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The frequency and width of the Lorentz oscillator are very close to those reported in Ref. [45], showing reliability of the method.

    “Additionally, both the frequency and the width of the Lorentz oscillator tend to be very close to the one reported in Ref. [45]-showing the reliability of the method.”
  • Estimating from the sample dimensions, the beam radius in [13] was of the order of 1-2 cm, which provides a Gouy shift correction of the refractive index of approximately 0.5-1 × 10^−4, consistent with the observed decrease in the refractive index in Fig. 4 of [13].

    “it is possible to estimate from the sample dimensions that the beam radius was of the order of 1–2 cm, which provides the Gouy shift correction of the refractive index of approximately 0.5–1 × 10−4, a value consistent with the observed decrease in the refractive index in Fig. 4 of [13].”
  • The retrieved background refractive index of the Si wafer, 3.415, agrees within 1 per mille with the most precise reported value of 3.4175 for high-resistivity silicon.

    “The value of 3.415 of the background refractive index of our Si wafer seems to be in a quite good agreement (difference smaller than 1 per mille) with the so far most precise value of 3.4175 reported for high-resistivity silicon [13].”

Cited by

Sorted by citations

Authors
Dai, J., Zhang, J., Zhang, W., & Grischkowsky, D.
Affiliations
Oklahoma State University (US)
Venue
Journal of the Optical Society of America B
Published
2004-07-01
Volume
21
Issue
7
Pages
1379
ISSN
  • 0740-3224 (ISSN-L)
  • 1520-8540
OpenAlex
W1987925546
Cited by
499
References
0
Citations by year
2026: 33 · 2025: 34 · 2024: 32 · 2023: 40 · 2022: 40 · 2021: 32 · 2020: 36 · 2019: 37 · 2018: 34 · 2017: 17 · 2016: 24 · 2015: 27 · 2014: 28 · 2013: 21 · 2012: 11
FWCI
1.95
Type
journal article
Language
en
Open access
closed
Locations
Journal of the Optical Society of America B (publishedVersion)
Funders
  • National Science Foundation
  • U.S. Department of Energy
  • Office of Experimental Program to Stimulate Competitive Research
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
Keywords
far-infrared absorption, refractive index, float-zone silicon, high-resistivity silicon, terahertz time-domain spectroscopy, refractive index dispersion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review