Terahertz time-domain spectroscopy characterization of the far-infrared absorption and index of refraction of high-resistivity, float-zone silicon
Abstract
The far-infrared absorption and index of refraction of high-resistivity, float-zone, crystalline silicon has been measured by terahertz time-domain spectroscopy. The measured new upper limit for the absorption of this most transparent dielectric material in the far infrared shows unprecedented transparency over the range from 0.5 to 2.5 THz and a well-resolved absorption feature at 3.6 THz. The index of refraction shows remarkably little dispersion, changing by only 0.0001 over the range from 0.5 to 4.5 THz.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The frequency and width of the Lorentz oscillator are very close to those reported in Ref. [45], showing reliability of the method.
“Additionally, both the frequency and the width of the Lorentz oscillator tend to be very close to the one reported in Ref. [45]-showing the reliability of the method.”
From THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters (2019) · cites this paper as [45]
Estimating from the sample dimensions, the beam radius in [13] was of the order of 1-2 cm, which provides a Gouy shift correction of the refractive index of approximately 0.5-1 × 10^−4, consistent with the observed decrease in the refractive index in Fig. 4 of [13].
“it is possible to estimate from the sample dimensions that the beam radius was of the order of 1–2 cm, which provides the Gouy shift correction of the refractive index of approximately 0.5–1 × 10−4, a value consistent with the observed decrease in the refractive index in Fig. 4 of [13].”
From Gouy shift correction for highly accurate refractive index retrieval in time-domain terahertz spectroscopy (2010) · cites this paper as [13]
The retrieved background refractive index of the Si wafer, 3.415, agrees within 1 per mille with the most precise reported value of 3.4175 for high-resistivity silicon.
“The value of 3.415 of the background refractive index of our Si wafer seems to be in a quite good agreement (difference smaller than 1 per mille) with the so far most precise value of 3.4175 reported for high-resistivity silicon [13].”
From Gouy shift correction for highly accurate refractive index retrieval in time-domain terahertz spectroscopy (2010) · cites this paper as [13]
Cited by
Sorted by citations
Terahertz spectroscopy and imaging - Modern techniques and applications
Jepsen, P. U., Cooke, D. G., & Koch, M. (2011) · Laser & Photonics Reviews · doi:10.1002/lpor.201000011 · Cited by 2,091 · see citing works
Jepsen, P. U., Møller, U., & Merbold, H. (2007) · Optics Express · doi:10.1364/oe.15.014717 · Cited by 245 · see citing works
Kužel, P., Němec, H., Kadlec, F., & Kadlec, C. (2010) · Optics Express · doi:10.1364/oe.18.015338 · Cited by 111 · see citing works
THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters
Peretti, R., Mitryukovskiy, S., Froberger, K., Mebarki, M. A., Eliet, S., Vanwolleghem, M., & Lampin, J.-F. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2889227 · Cited by 78 · see citing works
Uncertainty and ambiguity in terahertz parameter extraction and data analysis
Krüger, M., Funkner, S., Bründermann, E., & Havenith, M. (2011) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-010-9669-1 · Cited by 43 · see citing works
Linearity calibration of amplitude and power measurements in terahertz systems and detectors
Naftaly, M., & Dudley, R. (2009) · Optics Letters · doi:10.1364/ol.34.000674 · Cited by 40 · see citing works
Artificial neural networks for material parameter extraction in terahertz time-domain spectroscopy
Klokkou, N., Gorecki, J., Wilkinson, J. S., & Apostolopoulos, V. (2022) · Optics Express · doi:10.1364/oe.454756 · Cited by 34 · see citing works
Design and evaluation of a THz time domain imaging system using standard optical design software
Brückner, C., Pradarutti, B., Müller, R., Riehemann, S., Notni, G., & Tünnermann, A. (2008) · Applied Optics · doi:10.1364/ao.47.004994 · Cited by 15 · see citing works
Han, J. W. (2025) · Journal of Laser Applications · doi:10.2351/7.0001745 · Cited by 1 · see citing works
- Authors
- Dai, J., Zhang, J., Zhang, W., & Grischkowsky, D.
- Affiliations
- Oklahoma State University (US)
- Venue
- Journal of the Optical Society of America B
- Publisher
- Optica Publishing Group
- Published
- 2004-07-01
- Volume
- 21
- Issue
- 7
- Pages
- 1379
- ISSN
- 0740-3224 (ISSN-L)
- 1520-8540
- OpenAlex
- W1987925546
- Cited by
- 499
- References
- 0
- Citations by year
- 2026: 33 · 2025: 34 · 2024: 32 · 2023: 40 · 2022: 40 · 2021: 32 · 2020: 36 · 2019: 37 · 2018: 34 · 2017: 17 · 2016: 24 · 2015: 27 · 2014: 28 · 2013: 21 · 2012: 11
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the Optical Society of America B (publishedVersion)
- Funders
- National Science Foundation
- U.S. Department of Energy
- Office of Experimental Program to Stimulate Competitive Research
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
- Keywords
- far-infrared absorption, refractive index, float-zone silicon, high-resistivity silicon, terahertz time-domain spectroscopy, refractive index dispersion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review