The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Design of an optical see-through head-mounted display with a low f-number and large field of view using a freeform prism
Abstract
It has been a challenge to design an optical see-through head-mounted display (OST-HMD) that has a wide field of view (FOV) and low f-number (f/#) while maintaining a compact, lightweight, and nonintrusive form factor. In this paper, we present an OST-HMD design using a wedge-shaped freeform prism cemented with a freeform lens. The prism, consisting of three freeform surfaces (FFSs), serves as the near-eye viewing optics that magnifies the image displayed through a microdisplay, and the freeform lens is an auxiliary element attached to the prism in order to maintain a nondistorted see-through view of a real-world scene. Both the freeform prism and the lens utilize plastic materials to achieve light weight. The overall dimension of the optical system per eye is no larger than 25 mm by 22 mm by 12 mm, and the weight is 8 g. Based on a 0.61 in. microdisplay, our system demonstrates a diagonal FOV of 53.5 degrees and an f/# of 1.875, with an 8 mm exit pupil diameter and an 18.25 mm eye relief.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Merging virtual objects with the real world: seeing ultrasound imagery within the patient
Bajura, M., Fuchs, H., & Ohbuchi, R. (1992) · Proceedings of the 19th annual conference on Computer graphics and interactive techniques · doi:10.1145/133994.134061 · Cited by 520
Merging virtual objects with the real world: seeing ultrasound imagery within the patient
Bajura, M., Fuchs, H., & Ohbuchi, R. (1992) · ACM SIGGRAPH Computer Graphics · doi:10.1145/142920.134061 · Cited by 337
Scape: supporting stereoscopic collaboration in augmented and projective environments
Hua, H., Brown, L. D., & Gao, C.-Y. (2004) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2004.1255811 · Cited by 72
Self-citationEnhancing reality in the operating room
Lorensen, W. E., Cline, H. E., Nafis, C., Kikinis, R., Altobelli, D. E., & Gleason, L. (2002) · Visualization · doi:10.1109/visual.1993.398902 · Cited by 72
Using texture maps to correct for optical distortion in head-mounted displays
Watson, B. A., & Hodges, L. F. (2002) · IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vrais.1995.512493 · Cited by 70
New realities in aircraft design and manufacture
Sims, D. (1994) · IEEE Computer Graphics and Applications · doi:10.1109/38.267487 · Cited by 64
Cited by
Augmented reality and virtual reality displays: emerging technologies and future perspectives
Xiong, J., Hsiang, E.-L., He, Z., Zhan, T., & Wu, S.-T. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00658-8 · Cited by 1,286
Manufacturing and measurement of freeform optics
Fang, F. Z., Zhang, X. D., Weckenmann, A., Zhang, G. X., & Evans, C. (2013) · CIRP Annals · doi:10.1016/j.cirp.2013.05.003 · Cited by 823
Augmented reality applications in design and manufacturing
Nee, A. Y. C., Ong, S. K., Chryssolouris, G., & Mourtzis, D. (2012) · CIRP Annals · doi:10.1016/j.cirp.2012.05.010 · Cited by 762
Three-dimensional display technologies
Geng, J. (2013) · Advances in Optics and Photonics · doi:10.1364/aop.5.000456 · Cited by 714
Metasurface eyepiece for augmented reality
Lee, G.-Y., Hong, J.-Y., Hwang, S., Moon, S., Kang, H., Jeon, S., Kim, H., Jeong, J.-H., & Lee, B. (2018) · Nature Communications · doi:10.1038/s41467-018-07011-5 · Cited by 521
Metadata
- Authors
- Cheng, D., Wang, Y., Hua, H., & Talha, M. M.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 2009-05-05
- Volume
- 48
- Issue
- 14
- Pages
- 2655
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W1987710226
- Cited by
- 319
- References
- 7
- FWCI
- 4.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.