Far Infrared Measurement of the Dielectric Properties of GaAs and CdTe at 300 K and 8 K
The DOI matches its Crossref record.
Abstract
The real refractive index n and power absorption coefficient alpha of high resistivity GaAs and CdTe have been directly measured at 300 K and 8 K in the wavelength region from 12.5 micro to 300 micro. This spectral region contains the fundamental lattice resonance of both materials: 37.2 micro for GaAs and 71.4 micro for CdTe. This resonance causes large dispersion in the linear material properties. Single Drude-type oscillators have been visually fit to the measured n data with the results that for GaAs, epsilon(dc)' = 12.8 +/- 0.5 at 300 K and 12.6 +/- 0.5 at 8 K, and epsilonalpha(') = 10.9 +/- 0.4 at 300 K and 8 K ; for CdTe, epsilon(dc)' = 9.4 +/- 0.4 at 300 K and 9.0 +/- 0.4 at 8 K, and epsilon(alpha)' = 6.7 +/- 0.3 at 300 K and 8 K. The GaAs data clarifies the role of dispersion in n in the 5-20 micro region where previous results differ considerably. For both materials the n and alpha data in the region past 30 micro are the first to be reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Carrier dynamics in semiconductors studied with time-resolved terahertz spectroscopy
Ulbricht, R., Hendry, E., Shan, J., Heinz, T. F., & Bonn, M. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.543 · Cited by 1,293
“This brings some pivotal advantages in contrast to traditional far-infrared cw spectroscopy techniques that were commonly used before [see, e.g., Johnson et al. (1969) and Birch et al. (1974)].”
ResultElectron Mobility in Direct-Gap Polar Semiconductors
Rode, D. L. (1970) · Physical Review B · doi:10.1103/physrevb.2.1012 · Cited by 370
Design of tunable biperiodic graphene metasurfaces
Fallahi, A., & Perruisseau-Carrier, J. (2012) · Physical Review B · doi:10.1103/physrevb.86.195408 · Cited by 364
Duffy, S. M., Verghese, S., McIntosh, A., Jackson, A., Gossard, A. C., & Matsuura, S. (2001) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.925487 · Cited by 177
“The absorption was measured in the 1‐4-THz range and leads to approximately 28% loss at 2.7 THz [ 25 ], [26].”
BackgroundInfluentialEffects of Scattering on THz Spectra of Granular Solids
Bandyopadhyay, A., Sengupta, A., Barat, R. B., Gary, D. E., Federici, J. F., Chen, M., & Tanner, D. B. (2007) · International Journal of Infrared and Millimeter Waves · doi:10.1007/s10762-007-9276-y · Cited by 63
“It has been extensively employed to characterize the material parameters of various solids such as dielectrics, [1, 2] semiconductors, [3, 4] nanomaterials [5] and polymers.”
Background
Metadata
- Authors
- Johnson, C. J., Sherman, G. H., & Weil, R.
- Venue
- Applied Optics
- Publisher
- Optica Publishing Group
- Published
- 1969-08-01
- Volume
- 8
- Issue
- 8
- Pages
- 1667
- ISSN
- 0003-6935 (ISSN-L)
- 1539-4522
- OpenAlex
- W2080470506
- Cited by
- 108
- References
- 0
- FWCI
- 7.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.