Cited by 81Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesSpectroscopy Techniques in Biomedical and Chemical Research

Improved noncontact optical sensor for detection of glucose concentration and indication of dehydration level

Open access
Ozana, Nisan, Arbel, Nadav, Beiderman, Yevgeny, Mico, Vicente, Sanz, Martin, Garcia, Javier, Anand, Arun, Javidi, Baharam +2 more·2014·Biomedical Optics Express

Abstract

The ability to extract different bio-medical parameters from one single wristwatch device can be very applicable. The wearable device that is presented in this paper is based on two optical approaches. The first is the extraction and separation of remote vibration sources and the second is the rotation of linearly polarized light by certain materials exposed to magnetic fields. The technique is based on tracking of temporal changes of reflected secondary speckles produced in the wrist when being illuminated by a laser beam. Change in skin's temporal vibration profile together with change in the magnetic medium that is generated by time varied glucose concentration caused these temporal changes. In this paper we present experimental tests which are the first step towards an in vivo noncontact device for detection of glucose concentration in blood. The paper also shows very preliminary results for qualitative capability for indication of dehydration.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/boe.5.001926

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Measurement problem of hydration while moving can be solved with optical sensors together with a set of sensors measuring indirect hydration.

    “Lack of drinking can be easily detected from urine or blood, but collection cannot be performed while moving, but this measurement problem can be solved with the help of optical sensors together with a set of sensors that allow to measure the indirect method of hydration [46].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [46]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ozana, N., Arbel, N., Beiderman, Y., Mico, V., Sanz, M., Garcia, J., Anand, A., Javidi, B., Epstein, Y., & Zalevsky, Z.
Affiliations
  • Bar-Ilan University (IL)
  • Maharaja Sayajirao University of Baroda (IN)
  • University of Connecticut (US)
  • Tel Aviv University (IL)
Venue
Biomedical Optics Express
Published
2014-05-22
Volume
5
Issue
6
Pages
1926
ISSN
2156-7085 (ISSN-L)
OpenAlex
W2079051746
Cited by
81
References
21
Citations by year
2025: 5 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 8 · 2017: 6 · 2016: 10 · 2015: 29 · 2014: 2
FWCI
8.14
Type
journal article
Language
en
Open access
Locations
  • Biomedical Optics Express (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Repository of Digital Objects for Teaching Research and Culture (University of Valencia) (submittedVersion, other-oa)
Funders
  • Ministerio de Economía y Competitividad
  • European Regional Development Fund
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
blood glucose concentration, dehydration detection, optical sensors, speckle, skin vibration, linearly polarized light, magnetic recording media, laser reflection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review