Transparency of pair-correlated, random distributions of small scatterers, with applications to the cornea*
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
We consider transmission through pair-correlated random distributions of lossless dielectric (globular, cylindrical, or plate-like) scatterers with length parameter a and average spacing small compared to wavelength. Each optical particle is centered in a tough adherent transparent coating whose outer surface (sphere, cylinder, or slab) has radius b smaller than or equal to a. The corresponding attenuation coefficients beta varies directly as WM involve an integral of the appropriate radial-distribution function. Using the scaled-particle equations of state and statistical-mechanics theorems, we evaluate WM explicitly as a rational function of the volume fraction W of the fluid of rigid b particles. We obtain betaM = betaO WM with betaO as the uncorrelated value; W3(W) for spheres decreases more rapidly with increasing W than W2 for cylinders, and W2 decreases faster than W1, the result for slabs. We apply the results for cylinders in terms of W2 to the problem of the transparency of the cornea (whose collagen fibers are the scatters), as posed by Maurice. The value W APPROXIMATELY 0.6 GIVES GOOD ACCORD WITH THE ESSENTIALS OF THE Data for the transparency of the normal cornea, and the opacity that results from swelling is accounted for by corresponding smaller values of W. Thus, the normal cornea is modeled as a very densely packed two-dimensional gas, with gas-particle (mechanical) radius about 60% greater than the fiber (optical) radius.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Mechanics of Rigid Spheres
Reiss, H., Frisch, H. L., & Lebowitz, J. L. (1959) · The Journal of Chemical Physics · doi:10.1063/1.1730361 · Cited by 1,433
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129
Theory of Transparency of the Eye
Benedek, G. B. (1971) · Applied Optics · doi:10.1364/ao.10.000459 · Cited by 894
Packing of Spheres: Packing of Equal Spheres
SCOTT, G. D. (1960) · Nature · doi:10.1038/188908a0 · Cited by 830
Theory of the Two- and One-Dimensional Rigid Sphere Fluids
Helfand, E., Frisch, H. L., & Lebowitz, J. L. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1731629 · Cited by 387
Light scattering in the cornea
Hart, R. W., & Farrell, R. A. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000766 · Cited by 237
The transparency of the mammalian cornea
Cox, J. L., Farrell, R. A., Hart, R. W., & Langham, M. E. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009230 · Cited by 145
The equation of state of dense systems
Rowlinson, J. S. (1965) · Reports on Progress in Physics · doi:10.1088/0034-4885/28/1/306 · Cited by 121
Cited by
A literature review and novel theoretical approach on the optical properties of whole blood
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J. (2014) · Lasers in Medical Science · doi:10.1007/s10103-013-1446-7 · Cited by 459
Optical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
(1997) · PubMed · Cited by 326
Light scattering in strongly scattering media: Multiple scattering and weak localization
van der Mark, M. B., van Albada, M. P., & Lagendijk, A. (1988) · Physical Review B · doi:10.1103/physrevb.37.3575 · Cited by 308
Transparency, swelling and scarring in the corneal stroma
Meek, K. M., Leonard, D. W., Connon, C. J., Dennis, S., & Khan, S. (2003) · Eye · doi:10.1038/sj.eye.6700574 · Cited by 230
“Perfect crystal lattice Maurice (1957)(3) Uniform refractive index Smith (1969)(1) Short-range order Hart and Farrell (1969)(4) Average area/fibril=correlation area Benedek (1971)(8) Perturbed lattice Feuk (1971)(6) Hard-core fibrils with PG coating Twersky (1975)(7) Transparency, swelling, scarring in corneal stroma…”
Background
Metadata
- Authors
- Twersky, V.
- Venue
- Journal of the Optical Society of America
- Publisher
- Optica Publishing Group
- Published
- 1975-05-01
- Volume
- 65
- Issue
- 5
- Pages
- 524
- ISSN
- 0030-3941 (ISSN-L)
- OpenAlex
- W2124904543
- Cited by
- 159
- References
- 8
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.