Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 459

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

A literature review and novel theoretical approach on the optical properties of whole blood

Open access
Bosschaart, Nienke, Edelman, Gerda J., Aalders, Maurice C. G., van Leeuwen, Ton G., Faber, Dirk J.·2014·Lasers in Medical Science

Abstract

Optical property measurements on blood are influenced by a large variety of factors of both physical and methodological origin. The aim of this review is to list these factors of influence and to provide the reader with optical property spectra (250–2,500 nm) for whole blood that can be used in the practice of biomedical optics (tabulated in the appendix). Hereto, we perform a critical examination and selection of the available optical property spectra of blood in literature, from which we compile average spectra for the absorption coefficient (μ(a)), scattering coefficient (μ(s)) and scattering anisotropy (g). From this, we calculate the reduced scattering coefficient (μ(s)′) and the effective attenuation coefficient (μ(eff)). In the compilation of μ(a) and μ(s), we incorporate the influences of absorption flattening and dependent scattering (i.e. spatial correlations between positions of red blood cells), respectively. For the influence of dependent scattering on μ(s), we present a novel, theoretically derived formula that can be used for practical rescaling of μ(s) to other haematocrits. Since the measurement of the scattering properties of blood has been proven to be challenging, we apply an alternative, theoretical approach to calculate spectra for μ(s) and g. Hereto, we combine Kramers–Kronig analysis with analytical scattering theory, extended with Percus–Yevick structure factors that take into account the effect of dependent scattering in whole blood. We argue that our calculated spectra may provide a better estimation for μ(s) and g (and hence μ(s)′ and μ(eff)) than the compiled spectra from literature for wavelengths between 300 and 600 nm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10103-013-1446-7

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Metadata

Authors
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J.
Venue
Lasers in Medical Science
Published
2013-10-12
Volume
29
Issue
2
Pages
453-479
ISSN
  • 0268-8921 (ISSN-L)
  • 1435-604X
OpenAlex
W2028558873
Cited by
459
References
30
FWCI
13.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A literature review and novel theoretical approach on the optical properties of whole blood. https://app.cochat.ai/papers/10.1007/s10103-013-1446-7
The paper
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J. (2014). A literature review and novel theoretical approach on the optical properties of whole blood. Lasers in Medical Science. https://doi.org/10.1007/s10103-013-1446-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.