Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record.

Physical limits of acuity and hyperacuity

Geisler, Wilson S. · 1984 · Journal of the Optical Society of America A

Abstract

An ideal detector is derived for the discrimination of arbitrary stimuli in the two-alternative forced-choice paradigm. The ideal detector's performance is assumed to be limited only by quantal fluctuations, the optics of the eye, and the size and spacing of the receptors in the retinal mosaic. Detailed predictions are presented for two-point acuity and hyperacuity tasks. The ideal detector's two-point resolution, over a wide range of luminances, is approximately 10 times worse than its two-point vernier acuity or separation discrimination. Furthermore, two-point resolution is shown to vary in proportion to the -1/4 power of spot intensity, but vernier acuity and separation discrimination vary in proportion to the -1/2 power of spot intensity. It is shown that this ideal detector can be implemented by the use of appropriately shaped receptive fields. The derivation provides a simple way to determine the shapes of these optimal receptive fields for arbitrary stimuli. The sensitivities of real (human) and ideal detectors are compared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/josaa.1.000775

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Geisler, W. S.
Venue
Journal of the Optical Society of America A
Published
1984-07-01
Volume
1
Issue
7
Pages
775
ISSN
  • 1084-7529 (ISSN-L)
  • 1520-8532
OpenAlex
W2091131901
Cited by
163
References
0
FWCI
4.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physical limits of acuity and hyperacuity. https://app.cochat.ai/papers/10.1364/josaa.1.000775
The paper
Geisler, W. S. (1984). Physical limits of acuity and hyperacuity. Journal of the Optical Society of America A. https://doi.org/10.1364/josaa.1.000775

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.