The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensor
Abstract
A Hartmann-Shack wave-front sensor is used to measure the wave aberrations of the human eye by sensing the wave front emerging from the eye produced by the retinal reflection of a focused light spot on the fovea. Since the test involves the measurements of the local slopes of the wave front, the actual wave front is reconstructed by the use of wave-front estimation with Zernike polynomials. From the estimated Zernike coefficients of the tested wave front the aberrations of the eye are evaluated. It is shown that with this method, using a Hartmann-Shack wave-front sensor, one can obtain a fast, precise, and objective measurement of the aberrations of the eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave-front estimation from wave-front slope measurements
Southwell, W. H. (1980) · Journal of the Optical Society of America · doi:10.1364/josa.70.000998 · Cited by 985
Optical quality of the human eye
Campbell, F. W., & Gubisch, R. W. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008056 · Cited by 810
A subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
Objective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220
Evaluation of Large Aberrations Using a Lateral-Shear Interferometer Having Variable Shear
Rimmer, M. P., & Wyant, J. C. (1975) · Applied Optics · doi:10.1364/ao.14.000142 · Cited by 147
Cited by
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationAberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Self-citationMonochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Thibos, L. N., Hong, X., Bradley, A., & Cheng, X. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002329 · Cited by 622
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Metadata
- Authors
- Liang, J., Grimm, B., Goelz, S., & Bille, J. F.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1994-07-01
- Volume
- 11
- Issue
- 7
- Pages
- 1949
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2146209717
- Cited by
- 1,195
- References
- 5
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.