CoChat

Saccadic suppression of achromatic and chromatic responses measured by increment-threshold spectral sensitivity

Uchikawa, Keiji, Sato, Masayuki · 1995 · Journal of the Optical Society of America A
Cited by 92

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We measured spectral-sensitivity functions during saccadic eye movement by the increment-threshold method to test whether saccades selectively suppressed achromatic or chromatic responses. A circular monochromatic test stimulus of 12-deg diameter was presented for 10 ms on a 62 deg x 43 deg white background, and observations were made under three conditions: during fixation, during 6-deg saccades, and immediately after saccades. In two additional conditions the test stimulus was made to move during fixation and during 6-deg saccades at the same speed and in the same direction as the saccades. The during-fixation spectral-sensitivity function was found to resemble the relative luminous efficiency V (lambda) function in shape except for the case of short wavelengths, whereas the during-saccade spectral-sensitivity function showed lower sensitivity for all wavelengths and had three prominent peaks at approximately 440, 530, and 600 nm. These characteristics did not depend on whether the stimulus was stationary or moving. These results indicated that saccadic suppression was greater for achromatic than for chromatic response. A possible suppression mechanism was discussed involving the magno and parvo pathways.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/josaa.12.000661

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 92

Metadata

Authors
Uchikawa, K., & Sato, M.
Venue
Journal of the Optical Society of America A
Published
1995-04-01
Volume
12
Issue
4
Pages
661
ISSN
  • 1084-7529 (ISSN-L)
  • 1520-8532
OpenAlex
W2040278636
Cited by
92
References
2
FWCI
7.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.