The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Aberrations and retinal image quality of the normal human eye
Abstract
We have constructed a wave-front sensor to measure the irregular as well as the classical aberrations of the eye, providing a more complete description of the eye's aberrations than has previously been possible. We show that the wave-front sensor provides repeatable and accurate measurements of the eye's wave aberration. The modulation transfer function of the eye computed from the wave-front sensor is in fair, though not complete, agreement with that obtained under similar conditions on the same observers by use of the double-pass and the interferometric techniques. Irregular aberrations, i.e., those beyond defocus, astigmatism, coma, and spherical aberration, do not have a large effect on retinal image quality in normal eyes when the pupil is small (3 mm). However, they play a substantial role when the pupil is large (7.3-mm), reducing visual performance and the resolution of images of the living retina. Although the pattern of aberrations varies from subject to subject, aberrations, including irregular ones, are correlated in left and right eyes of the same subject, indicating that they are not random defects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationLiang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Self-citationWave-front estimation from wave-front slope measurements
Southwell, W. H. (1980) · Journal of the Optical Society of America · doi:10.1364/josa.70.000998 · Cited by 985
Optical quality of the human eye
Campbell, F. W., & Gubisch, R. W. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008056 · Cited by 810
The luminous efficiency of rays entering the eye pupil at different points
Stiles, W. S., & Crawford, B. H. (1933) · Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character · doi:10.1098/rspb.1933.0020 · Cited by 689
A subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
Objective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220
Images of cone photoreceptors in the living human eye
Miller, D. T., Williams, D. R., Morris, G. M., & Liang, J. (1996) · Vision Research · doi:10.1016/0042-6989(95)00225-1 · Cited by 184
Self-citationThe effect of pupil centration and diameter on ocular performance
Walsh, G., & Charman, W. N. (1988) · Vision Research · doi:10.1016/0042-6989(88)90114-9 · Cited by 89
Cited by
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
Self-citationPupillometry: Psychology, Physiology, and Function
Mathôt, S. (2018) · Journal of Cognition · doi:10.5334/joc.18 · Cited by 900
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Self-citationThibos, L. N., Hong, X., Bradley, A., & Cheng, X. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002329 · Cited by 622
Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
Artal, P., Berrio, E., Guirao, A., & Piers, P. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.000137 · Cited by 494
Metadata
- Authors
- Liang, J., & Williams, D. R.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1997-11-01
- Volume
- 14
- Issue
- 11
- Pages
- 2873
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2151084406
- Cited by
- 764
- References
- 11
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.